SEISMIC EVALUATION OF RESIDENTIAL BUILDING WITH MASONRY WALL USING ETABS

Abstract

 Past earthquakes showed poor performance of reinforced concrete framed buildings infilled with masonry wall. This study focuses on the evaluation of G+3 storeyed residential Reinforced Concrete (RC) building with brick masonry wall subjected to earthquake load. The influence of masonry on the seismic resistance of RC building is studied. The strut action with different percentage of opening for doors and windows are analysed. The building is assumed to be located in seismic zone III. The building is designed as per IS 456-2000 and the lateral loads are determined as per sixth revision of IS 1893(Part 1)-2002. This study is carried out with nonlinear parameters using pushover analysis in ETABS.

Authors and Affiliations

G. Prasanna Lakshmi*

Keywords

Related Articles

 EQUILIBRIUM AND KINETIC STUDIES OF BIOSORPTION OF REACTIVEORANGE 13 FROM AQUEOUS SOLUTION BY DEAD BIOMASS OF RHIZOPUSARRHIZUS

 The equilibrium and kinetics of the biosorption of Reactive Orange 13from aqueous solution were investigatedusing dead biomass of Rhizopus arrhizus in a batch system. Biosorption equilibrium was established in abou...

Study on the use of Recycled Aggregate in concrete

Recycling is the act of processing the used material for use in creating new product. The usage of natural aggregate is getting more and more intense with the advanced development in infrastructu of natural aggregate,...

 Mobile Printing using near Field Communication

 In Over the last year there have been countless developments related to new mobile phones, tablets, and apps for personal and business use alike. While the majority of these developments have nothing to do with pr...

MITIGATING HELLO FLOOD ATTACK ON WSN BY LEACH PROTOCOL USING ENERGY LEVEL

Various Wireless sensor network applications use hierarchical routing protocol for routing sensed data to sink. LEACH (Low energy adaptive clustering Hierarchical) is one of the broadly used hierarchical, distributed...

IMPLEMENTATION OF ADDRESS GENERATOR FOR WiMAX DEINTERLEAVER ON FPGA

In this paper, a low - complexity and novel technique is proposed to implement the address generation circuitry of 2 - D deinterleaver used in the WiMAX transreceiver using the Xilinx field - programmable gate arra...

Download PDF file
  • EP ID EP143831
  • DOI 10.5281/zenodo.51966
  • Views 70
  • Downloads 0

How To Cite

G. Prasanna Lakshmi* (30). SEISMIC EVALUATION OF RESIDENTIAL BUILDING WITH MASONRY WALL USING ETABS. International Journal of Engineering Sciences & Research Technology, 5(5), 806-813. https://europub.co.uk/articles/-A-143831