Abstract:Seismic damage showed that the effect of earthquake damages on urban lifeline system is much larger than other disasters. Shell element model of four nodes was used to simulate the buried pipeline, and the interaction between soil and pipeline was simulated by nonlinear soil spring, seismic response of buried variable-diameter pipeline under strike slip fault was analyzed by using finite element software ADINA. Through studying the influence of concentric and eccentric variable-diameter on seismic response of pipeline, the conclusion was obtained that seismic capacity of concentric variable-diameter pipeline is better than that of eccentric variable-diameter. The results of research provide a certain guiding for the seismic design of buried variable-diameter pipeline across the fault. Keywords:variable-diameter pipeline; strike slip fault; concentric variable-diameter; eccentric variable-diameter.

Authors and Affiliations

Jing-hong Xue, Yan-peng Lou, Xin Wang

Keywords

Related Articles

Computerization of the Students’ Industrial Work Experience Scheme (SIWES) Registration and Payment System (SIWES-RPS) in Nigeria

The current registration and payment processes for the Student Industrial Work Experience Scheme is semi-automated if not completely manual. Students have to queue at the Student’s Industrial Work Experience Scheme (SIWE...

A Study on Resource Allocation in Cloud

Cloud computing ia a type of internet based computing that is relies on sharing of computer resource from anywhere and anytime. It is similar to utility computing. In this paper a review of various policies for dynamic...

Prediction Method on Wellbore Stability Based on Analytic Hierarchy Process and Fuzzy Evaluation

Wellbore stability are influenced by many complex factors, and there is no commonly used prediction method on wellbore stability until now. Use of an efficient decision making technique which can take into account severa...

Mild Steel Corrosion Inhibition by Plant Extract in 0.1 M Hydrochloric Acid Solution

Extract of Clerodendrumphlomidis plants leaves was investigated as corrosion inhibitor of mild steel in 0.5M HCl using conventional weight loss method and scanning electron microscopic studies. The weight loss results sh...

A High Efficient Method of GIS Spatial Data Conversion

At present, most historical surveying data are stored with CAD format, so they can’t be used directly in GIS. This paper focused researches the data format of the CAD and ArcGIS, introduces several methods of data conver...

Download PDF file
  • EP ID EP385489
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

Jing-hong Xue, Yan-peng Lou, Xin Wang (2016). Seismic Response of Buried Pipeline across the Fault for Two Kinds of Variable-Diameter. Scholars Journal of Engineering and Technology, 4(5), 254-257. https://europub.co.uk/articles/-A-385489