Selecting the number of frequencies for real time electroimpedancemetry of biological objects

Abstract

Introduction. Determining the sufficient number of frequencies for biological object impedance measuring is being researched. The presence of one or two object granularities is considered. Formulation of the problem. Often impedance measuring is conducted in a real time conditions. The number of frequencies directly influences measuring time. Existing studies of frequencies quantity were based on a coarse Krike and Morse impedance model. Research methods and the results analysis. This work offers method for calculating the sufficient number of impedance measuring freqencies for biological object, which contains one or two granularities. Conclusions. Sufficient number of frequencies for the object containing one or two granularities was evaluated. Also path for discovering the case three and more granularities was prompted.

Authors and Affiliations

G. Timoshenko

Keywords

Related Articles

Electronically methods and facilities of lungs auscultation

Disadvantage of the traditional means of pulmonology are considered. Electroacoustic and biomechanical ways of registration breath sounds on chest surface are analyzed. The block diagram of the switch-modulation device f...

Direct digital method of the correlation-interferometric radio direction-finding with reconstructing of spatial analytical signal

In this paper, a new direct digital method of the correlation-interferometric radio direction-finding with reconstructing of spatial analytical signal is designed. Proposed method due to the previous parallel spatial sel...

Segmentation of anatomical heart structures in Ensite Verismo software for radiofrequency ablation of arrhythmogenic tissues

Review of the problem. The relevance of the research is the need of a high-quality imaging of the left atrium anatomy for the effectiveness of radiofraquency ablation of arrhythmogenic tissue of the myocardium in real ti...

Modeling of Electromechanical Characteristics of Piezoresonance Pressure Sensors with Membrane Control of the Interelectrode Gap of a Piezoelectric Element

The paper considers the issues of increasing the simulation accuracy of perspective piezoresonance overpressure sensors with membrane control of the piezoelectric element interelectrode gap. A comparative analysis of ela...

Radioholographic motion sensor

The new principle of constructing of the motion sensor which  fixes a repositioning of objects in considered radiation zone, is examined. It is offered to watch a repositioning of objects behind change of a phase of the...

Download PDF file
  • EP ID EP309102
  • DOI 10.20535/RADAP.2013.55.118-127
  • Views 86
  • Downloads 0

How To Cite

G. Timoshenko (2013). Selecting the number of frequencies for real time electroimpedancemetry of biological objects. Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування, 0(55), 118-127. https://europub.co.uk/articles/-A-309102