Selection of Best Fit Correlation for Compression Index of Soil from District Bannu

Abstract

Geotechnical investigation is one of the major steps in the safe and economic design of foundation for any structure. This requires some soil parameters to be established. CI (Compression Index) is one of these parameters. The stability of a foundation is not fully justified as long as the magnitude of settlement is unknown. The problem arises when the value of CI is needed badly and a consolidation test is set up for this purpose which consumes almost 3 days for its completion provided that the assembly would not be disturbed. Little amount of disturbance can cause serious error in further calculations and plotting of data. Undisturbed soil sample is the primary demand of consolidation test which is a tough job for a person having not been experienced very much in the fieldwork. In order to overcome these complexities, the researchers have established various correlations between compression index and some basic soil properties like Atterberg limits, void ratio, natural moisture content and OMC (Open Moisture Content), as they are simple to be determined and takes small amount of time. This research has been conducted on soil samples collected from a single spot at an interval of 5ft depth for the sake of validation of a suitable correlation for Bannu District, KPK (Khyber Pakhtunkhwa), Pakistan so that the determination of compression index becomes simple and convenient.

Authors and Affiliations

Zia-ur- Rahman, Siraj- Uddin, A. A. Khan, Mati Ullah

Keywords

Related Articles

Monitoring the Wastewater Treatment Efficiency of Oxidation Ponds at Chokera, Faisalabad

Treatment efficiency of the sewage stabilization ponds at Chokera, Faisalabad was carried out with respect to the parameters (i.e. BOD5 (Five Days Biochemical Oxygen Demand), COD (Chemical Oxygen Demand), pH, Turbidity,...

Evaluation of Urban Bus Transport Failure in Gujranwala City of Pakistan

This research work has evaluated the performance of urban public bus transport service operating in Gujranwala city of Pakistan. The assessment has been made in terms of financial viability, bus condition, operational pe...

A Flexible Architecture for Urdu Phonemes-Based Concatenative Speech Synthesis

TTS (Text-to-Speech) synthesis systems are extensively used across the world to intensify the accessibility of information and to make it possible for the handicapped to be involved directly with computers to get the ben...

A Study to Investigate the Consumer Behavior and Cultural Dimensions of Engineering Students in Pakistan

The current study compares consumer behavior and Cultural Orientations between engineering and non-engineering students in Pakistan. Engineering students by virtue of their academic background are considered to have more...

Calibration and Validation of an Experimental Setup for the Measurement of the Cylindrical Body Shapes and Curvatures of the Objects and Subjects through the Techniques of Rasterstereography

The intent of study is to establish a criterion for the experimental setup of rasterstereography, one that is more efficient, simple, accurate and precise to examine and analyse the curvature of the object or the subject...

Download PDF file
  • EP ID EP445197
  • DOI 10.22581/muet1982.1901.18
  • Views 98
  • Downloads 0

How To Cite

Zia-ur- Rahman, Siraj- Uddin, A. A. Khan, Mati Ullah (2019). Selection of Best Fit Correlation for Compression Index of Soil from District Bannu. Mehran University Research Journal of Engineering and Technology, 38(1), 221-226. https://europub.co.uk/articles/-A-445197