SELECTION OF TEST METHOD TO QUANTIFY WORKABILITY OF CEMENT PASTE AND MORTAR FOR VERY LOW WORKABLE TO HIGH WORKABLE MIX

Abstract

Cement paste and mortar fresh properties governs concrete characteristics.Selection of test method to measure workability is based on mix characteristic. Very low workability mix test method differs from the high workable mix.First attempt was made by authors to develop correlation between two tests and cover entire range of workability i.e. from very low to high workable mix. Mini flow table testand marsh cone test were selected for cement pasteand mortar.Marsh cone test is applicable beyond W/C ratio 0.50 for cement paste. Mini flow table test shows same flow diameter above W/C ratio 0.50 for cement paste. It is possible to evaluate flow behaviour of cement paste up toW/C ratio 0.62 by modifying cement paste cone volume.Marsh cone test was applicable beyondW/C ratio 0.72 for cement mortar having cement to fine aggregate proportion 1:1. Mini flow table test has diameter 250mm which is useful to measure low to medium workable mix of mortar. High workable cement mortar mixture spread is more than 250mm therefore it is necessary to do dimension change in mini flow table test. Modified mini flow table test having diameter of 450mm was applicable for entire range i.e. very low to high workable mix

Authors and Affiliations

Parth Thaker

Keywords

Related Articles

 A SECURITY OF CLOUD DATA IN FULLY HOMOMORPHIC ENCRYPTION

 The advancement in technology, industry, e-commerce and research. A large amount of complex and pervasive digital data is being generated which is increasing at an exponential rate and often termed as Big data. Fo...

 THREE DIMENSIONAL STRESS STATE OF SMART COMPOSITE LAMINATED CROSS PLY USING HSDT WITH ZIG ZAG FUNCTION

 Thermal analysis of smart composite laminated plate using higher order theory with zig zag function. To develop the analytical procedure and to investigate the thermal characteristics for a three dimensional cross...

Implementation of Power Line Communication for energy measurement

Power line communication (PLC), also known as power line carrier, is a system for transmitting information on an electrical conductor used for carrying electric power from high voltage transmission lines, distribution l...

 APPLICATION OF REMOTE SENSING AND GIS TECHNIQUES FOR GROUND WATER POTENTIAL ZONES MAPPING IN AIZAWL DISTRICT, MIZORAM, INDIA

 Availability of groundwater in an area depends largely upon the terrains. Mizoram state is blessed with abundant rainfall and number of perennial streams. However, large amount of rain water is lost through runoff...

Experimental Performance of Window Air Conditioner Using Alternative Refrigerants with Different Configurations of Capillary Tube A Review

This review paper presents the work of various researches on the performance of capillary tube ,used in air conditioners with various refrigerants. Research carried out by different authors uses different type of capill...

Download PDF file
  • EP ID EP122818
  • DOI -
  • Views 83
  • Downloads 0

How To Cite

Parth Thaker (2015). SELECTION OF TEST METHOD TO QUANTIFY WORKABILITY OF CEMENT PASTE AND MORTAR FOR VERY LOW WORKABLE TO HIGH WORKABLE MIX. International Journal of Engineering Sciences & Research Technology, 4(12), 854-860. https://europub.co.uk/articles/-A-122818