Semiautomatic Determination of Arterial Input Function in DCE-MRI of the Abdomen

Journal Title: Journal of Biomedical Engineering and Medical Imaging - Year 2017, Vol 4, Issue 2

Abstract

The goal of this study was to develop a semiautomatic segmentation technique of the abdominal aorta to determine the arterial input function (AIF). A total of 24 patients having therapy naïve abdominal cancers were imaged using DCE-MRI on a 3T MR scanner. DCE-MRI continued for 4.2 minutes with 2.1 seconds temporal resolution (120 acquisitions). Gadoteridol (0.1 mmol/kg) was infused intravenously at 30 seconds after starting DCE-MRI, and flushed with 20-ml saline (2 ml/s). Patients were instructed to hold breath after maximal inhalation, and repeat as needed to full inspiration. The location of the abdominal aorta was manually identified, but its segmentation and motion tracking were automatically implemented. AIFs determined in the aortic region with and without tracking motion were statistically compared. The aortic region was further segmented into multiple smaller regions, and the AIF change according to the size of the region of interest (ROI) was examined. The displacement of the abdominal aorta during DCE-MRI was 3.4±2.3 (mean±SD) mm. The root mean square error (RMSE) of AIF from the best fitting curve was 0.110±0.010 mM after motion correction, which was significantly smaller than that before motion correction (0.134±0.016 mM; p<0.001). The amplitude of AIF varied up to 15% according to the ROI size. However, when the radius of ROI was reduced more than 3 mm, the variation in AIF amplitude was less than 5%. Therefore the ROI having smaller radius than that of aorta will need to be used to determine a reliable AIF in abdominal DCE-MRI.

Authors and Affiliations

Harrison Kim

Keywords

Related Articles

Creation of 3D Volume Loss Mask and Mean Performance Analysis on 3d MR Images

Examination of changes in the brain during disease progression using numerical methods is one of the current topics investigated by neuroscience. One of the numerical methods developed for locally or globally analyzing c...

Evolution Via EPR-Entanglement Algorithm

By quantifying EPR-generated accumulations of entangled proton qubits populating duplex microsatellite base pairs, observed as G-C → G'-C', G-C → *G-C* and A-T → *A-*T, the potential to exhibit expansion or contraction o...

A Effectual Technique of Impulse Noise Suppression for Assessing the Impact of Brain Disorders in MRI by applying Selective Weighted Median Filter

An accurate analysis of medical images is progressively demanding in providing the absolute detection and diagnosis of diseases in medical imaging. The significant pre-processing step in MRI data processing is noise elim...

WBAN Mitigation Method: Comparison of Diversity Techniques in Fading

In WBAN various sensors and actuators are connected together either on the body, under the skin of person or on the clothes of the person. This network expands when the signals from the body are picked and sent over a wi...

Calculation of Talocrural Joint Axis Motion by Approximating Trochlea Tali with Conical Side Surface

The motion of the talus, the most complex and important bone in ankle motion, is determined by the geometric characteristics of the articular surface of the talocrural joint, known as the trochlea tali. Therefore, modeli...

Download PDF file
  • EP ID EP296542
  • DOI 10.14738/jbemi. 42.3041
  • Views 84
  • Downloads 0

How To Cite

Harrison Kim (2017). Semiautomatic Determination of Arterial Input Function in DCE-MRI of the Abdomen. Journal of Biomedical Engineering and Medical Imaging, 4(2), 96-104. https://europub.co.uk/articles/-A-296542