Sequence-based typing of Legionella pneumophila strains isolated from hospital water distribution systems as a complementary element of risk assessment of legionellosis in Poland

Journal Title: Annals of Agricultural and Environmental Medicine - Year 2013, Vol 20, Issue 3

Abstract

Many factors affect the risk of Legionella infection, such as the design, construction and maintenance of water distribution systems, the presence of individuals who may be exposed and their vulnerability to infection, and the degree of water system colonization and properties of Legionella strains. For epidemiological investigations, two properties of the Legionella strains are usually determined: serotyping and genotyping (sequence-based typing, SBT). In Poland, data regarding legionellosis are fragmentary, despite the fact that this has been a notifiable disease since 2002. The number of reported cases is very low; moreover, the main method of diagnosis is serological examination (delayed diagnosis and cheaper methods), and only single cases of LD were confirmed by culture of bacteria. Therefore, after 10 years of mandatory reporting of the Legionella spp. infection in Poland, the real epidemiological situation is still unknown; however, risk assessment should be carried out, especially in hospitals. In the presented study, comparison of the sequence types of 111 isolated L. pneumophila strains (from hospital water systems) with those present in the EWGLI SBT data was undertaken for complex risk analysis as a complementary element. In total, strains of L. pneumophila belonging to 12 out of 19 STs determined in the presented study were previously reported to the EWGLI SBT database (ST1, ST42, ST59, ST81, ST87, ST114, ST152, ST191, ST371, ST421, ST461, ST520). Among these strains, only 7 STs were previously reported in the amount of ≥10 (mainly ST1, ST42, ST81). Analysis of EWGLI data were carried out and, proportionally, the highest percentage of hospital-acquired strains (clinical and environmental) was found for ST 81, ST421 and ST152, but the largest number was for ST1. Based on the EWGLI data and the presented results, it was found that persistent colonization of HWS of 3 hospitals by strains belonging to ST42, ST1, ST87 indicated an increased risk of legionellosis, especially ST42.

Authors and Affiliations

Katarzyna Pancer

Keywords

Related Articles

Epidemiology of human toxocariasis in Poland – A review of cases 1978–2009

Toxocariasis is a helminthozoonosis due to the infection of humans with larvae belonging to the [i]Toxocara[/i] genus. Humans become infected as a result of accidental consumption of infected eggs containing third stage...

Host response to <em>Borrelia afzelii</em> in BALB/c mice tested by immunoblotting

The aim was to find if there is variability in the production of specific antibodies by BALB/c mice to certain antigens of three individual [i]Borrelia afzelii[/i] (dead cell suspension) strains originally isolated from...

Molecular aerobiology – [i]Plantago[/i] allergen Pla l 1 in the atmosphere

introduction. Exposure to airborne pollen from certain plants can cause allergic disease, but allergens can also be found in non-pollen-bearing fractions of ambient air. This may explain why the allergic response in susc...

In vitro evaluation of the effect of tobacco smoke on rat cornea function

The influence of tobacco smoke on the dielectric properties of rat cornea were measured[i] in vitro[/i] over the frequency range of the electric field of 500Hz–100kHz and in temperatures of the air from 25 to 150°C. The...

Download PDF file
  • EP ID EP80645
  • DOI -
  • Views 107
  • Downloads 0

How To Cite

Katarzyna Pancer (2013). Sequence-based typing of Legionella pneumophila strains isolated from hospital water distribution systems as a complementary element of risk assessment of legionellosis in Poland. Annals of Agricultural and Environmental Medicine, 20(3), 436-440. https://europub.co.uk/articles/-A-80645