Serum paraquat concentration detected by spectrophotometry in patients with paraquat poisoning

Journal Title: World Journal of Emergency Medicine - Year 2011, Vol 2, Issue 3

Abstract

BACKGROUND: Paraquat (PQ) is a world-wide used herbicide and also a type of common poison for suicide and accidental poisoning. Numerous studies have proved that the concentration of serum PQ plays an important role in prognosis. Spectrophotometry, including common spectrophotometry and second-derivative spectrophotometry, is commonly used for PQ detection in primary hospitals. So far, lack of systematic research on the reliability of the method and the correlation between clinical features of patients with PQ poisoning and the test results has restricted the clinical use of spectrophotometry. This study aimed to evaluate the reliability and value of spectrophotometry in detecting the concentration of serum PQ. METHODS: The wavelengths for detecting the concentration of serum PQ by common and second-derivative spectrophotometry were determined. Second-derivative spectrophotometry was applied to detect the concentration of serum PQ. The linear range and precision for detection of PQ concentration by this method were confirmed. The concentration of serum PQ shown by secondderivative spectrophotometry and HPLC were compared in 8 patients with PQ poisoning. Altogether 21 patients with acute poisoning 4 hours after PQ ingestion treated in the period of October 2008 to September 2010 were retrospectively reviewed. The patients were divided into higher and lower than 1.8 μg/mL groups based on their concentrations of serum PQ measured by second-derivative spectrophotometry on admission. The severity of clinical manifestations between the two groups were analyzed with Student's t test or Fisher's exact test. RESULTS: The absorption peak of 257 nm could not be found when common spectrophotometry was used to detect the PQ concentration in serum. The calibration curve in the 0.4-8.0 μg/mL range for PQ concentration shown by second-derivative spectrophotometry obeyed Beer's law with r=0.996. The average recovery rates of PQ were within a range of 95.0% to 99.5%, relative standard deviation (RSD) was within 1.35% to 5.41% (n=6), and the lower detection limit was 0.05 μg/mL. The PQ concentrations in serum of 8 patients with PQ poisoning shown by second-derivative spectrophotometry were consistent with the quantitative determinations by HPLC (r=0.995, P<0.0001). The survival rate was 22.2% in patients whose PQ concentration in serum was more than 1.8 μg/mL, and the incidences of acidosis, oliguria and pneumomediastinum in these patients were 55.6%, 55.6% and 77.8%, respectively. These clinical manifestations were different significantly from those of the patients whose PQ concentration in serum was less than 1.8 μg/mL (P<0.05). CONCLUSIONS: For common spectrophotometry, the wavelength at 257 nm was not suitable for detecting serum PQ as no absorbance was shown. Second-derivative spectrophotometry was reliable for detecting serum paraquat concentration. Serum PQ concentration detected by secondderivative spectrophotometry could be used to predict the severity of clinical manifestations of patients with PQ poisoning, and PQ content higher than 1.8 μg/mL 4 hours after ingestion could be an important predictive factor for poor prognosis.

Authors and Affiliations

Keywords

Related Articles

Emergency physician's perception of cultural and linguistic barriers in immigrant care: results of a multiple-choice questionnaire in a large Italian urban emergency department

BACKGROUND: A poor communication with immigrants can lead to inappropriate use of healthcare services, greater risk of misdiagnosis, and lower compliance with treatment. As precise information about communication between...

Clinical factors in patients with ischemic versus hemorrhagic stroke in East China

BACKGROUND: Stroke is one of the leading causes of mortality and morbidity of vascular diseases, and its incidence maintains at a high level around the world. In China, stroke has been a major public health problem. Beca...

Poor performance of the modified early warning score for predicting mortality in critically ill patients presenting to an emergency department

BACKGROUND: This study was undertaken to validate the use of the modified early warning score (MEWS) as a predictor of patient mortality and intensive care unit (ICU)/ high dependency (HD) admission in an Asian populatio...

Blunt injury to the thyroid gland: A case of delayed surgical emergency

Blunt trauma to the thyroid gland is a possibly life-threatening condition known for years. However, only few cases have been reported in the English-language literature, so that no consensus has emerged as to its workup...

Characteristics of non-conveyance ambulance runs: A retrospective study in the Netherlands

Emergency medical services (EMS) have developed from conveyance facilities into providers of advanced pre-hospital care.[1,2] Alongside this development there is a growing demand for EMS care, and the number of ambulance...

Download PDF file
  • EP ID EP473659
  • DOI -
  • Views 49
  • Downloads 0

How To Cite

(2011). Serum paraquat concentration detected by spectrophotometry in patients with paraquat poisoning. World Journal of Emergency Medicine, 2(3), 179-184. https://europub.co.uk/articles/-A-473659