Setting the range of reactive power regulation for a salient-poles motor based on the measurement of the synchronous work state
Journal Title: Mining – Informatics, Automation and Electrical Engineering - Year 2016, Vol 527, Issue 3
Abstract
The article features a method of determining synchronous reactance in the axes d and q for a synchronous motor with salient poles based on measuring basic electrical quantities in the state of synchronous work. The admissible operating range of the machine was discussed. The motor with salient poles was described by means of a phasor diagram. The author presented dependencies which allow to determine the solution searched for. The method was presented in a graphical manner. Finally, the author discussed the possibility to reduce the search range of available solutions.
Authors and Affiliations
Marian Hyla
Data transmission from electronic current transducers to a process bus in the IEC 61850 standard
The IEC 61850 standard is used more and more commonly now in the implementation of new distribution stations or modernization of the existing ones. One of the major aspects in proper functioning of such systems is the me...
Machine vision monitoring and particle size feed analysis
This paper presents selected problems related to the use of machine vision techniques for the analysis of particle size distribution. The basic steps and conditions for acquiring granular material images are described, f...
Digitization of Polish mining industry by reducing costs and improving safety and quality of finished product
This paper presents the current level of digitization of the Polish mining industry on examples of copper and hard coal mines. A proposal to digitize the individual business processes in mining production was presented....
Modern technologies of galvanic separation of digital signals and their possible applications in intrinsically safe devices
The article presents the reasons why the approach to separation has changed. Based on the solutions by Analog Devices and Texas Instruments, state-of-the-art technologies of galvanic separation of digital signals were pr...
The effect of duty type on current-carrying capacity of mining power cables
The methodology for determining intermittent or short-time current-carrying capacity has been described in the article. Results of current rating calculations for a short-time load and the time of cooling to an ambient t...