Shear bond strength of brackets bonded with different LED units & curing times and at different debond times in an in-vitro study

Journal Title: Journal of Advanced Medical and Dental Sciences Research - Year 2017, Vol 5, Issue 8

Abstract

Objective: The study compared 2 Light Emitting Diode (LED) curing units with a universal testing machine for checking the shear bond strength and also evaluated adhesive remnant index (ARI). Methods: This in vitro study was carried out on sound 120 human extracted premolars. All the teeth were bonded with adhesive precoated metal brackets. The brackets were instantly set in place and confidently pressed against the tooth surfaces and polymerization of brackets was done with LED curing units [VALO and ELIPAR]. Both groups were further divided according to different debond times. SBS values in all the cases were measured at a crosshead speed of 1 mm/min and a 50-kg load cell. Significance for all statistical tests was pre-determined at p < .05. Results: In-vitro bond strengths for the LED curing units (Elipar and VALO) were 8.84±3.141 MPa and 9.87±5.591 MPa, respectively. Moreover, the shear bond strength was improving with time from 12 hours to 7 days in both the units. An equivalent distribution of the ARI (Adhesive Remnant Index) scores of 0, 1, and 3 was noticed for all debond times but an ARI score of 2 was not observed in this group. However, in LED unit (VALO) all the ARI scores (0, 1, 2, 3) were observed at different deboning times. Conclusions: The results revealed that the shear bond strength (MPa) improved with time from 12 hours to 7 days in both the curing units

Authors and Affiliations

Chanamallappa Ramappa Ganiger, Yusuf Ahammed A. R, Vikram Shetty

Keywords

Related Articles

A Cross Sectional Study among Private Dental Practitioners Regarding Radiation Protection: Questionnaire Based Survey

Background and Aim: Radiation is the transmission of energy through space and matter. Even though they provide useful information and aid in diagnosis, they have the potential to cause harmful effects. This study aimed t...

ASSESSMENT OF COMPLICATIONS OCCURRING IN PATIENTS UNDERGOING ORTHODONTIC EXTRACTION OF MAXILLARY FIRST PREMOLARS USING ABSORBABLE COLLAGEN SPONGES IN EXTRACTION SOCKETS

Background: Angle favored non-extraction orthodontic treatment based on the concept of the occlusion line, in early eighteenth century. Special post-operative care is taken by surgeons while doing extractions to avoid co...

MICROBIOLOGICAL PROFILE IN URINARY TRACT INFECTIONS AMONG CHILDREN

Background: Urinary tract infection (UTI) is a typical bacterial contamination in kids. Early determination, treatment in light of the anti-microbial affectability example of the causative microorganisms and assessment f...

Comparative Analysis of Pain Response at Fasting and Postprandial in Young Diabetic Adults

Background: Diabetes is one of the leading causes of mortality globally. According to World Health Organization statistics published in 2013, approximately 347 million people worldwide suffer from diabetes, and by 2030 d...

Management of Post- operative Scar Pain by use of Triamcinolone Acetonide Injection

Background: Scars result from the biological process of wound repair in the skin, as well as in other organs and tissues of the body. Triamcinolone acetonide (TAC) is a synthetic corticosteroid used topically to treat va...

Download PDF file
  • EP ID EP560989
  • DOI -
  • Views 109
  • Downloads 0

How To Cite

Chanamallappa Ramappa Ganiger, Yusuf Ahammed A. R, Vikram Shetty (2017). Shear bond strength of brackets bonded with different LED units & curing times and at different debond times in an in-vitro study. Journal of Advanced Medical and Dental Sciences Research, 5(8), 66-69. https://europub.co.uk/articles/-A-560989