SIMPLE METHOD OF 3D ERROR COMPENSATION OF TRIGGERING PROBES ON COORDINATE MEASURING MACHINE

Journal Title: Metrology and Measurement Systems - Year 2006, Vol 13, Issue 3

Abstract

In this study an automatic, simple algorithm of systematic error corrections of a CMM touch triggering probe is proposed. The whole process does not exceed a standard calibration procedure done on coordinate machine before each measuring task. The tests show that the application of the proposed method will allow reducing fourfold the systematic errors of probe performance.

Authors and Affiliations

ADAM WOŹNIAK

Keywords

Related Articles

DESIGN OF A THERMAL WATTMETER IN THE AUDIO FREQUENCY RANGE

This paper describes the development of a system for the measurement of power in the audio frequency range. Flexible units operating with a strategy based on the evaluation of rms quantity by a thermal method have been c...

NONLINEAR CURRENT OSCILLATIONS IN A JOSEPHSON JUNCTION WITH FRACTAL RADIOISOTOPE COMPOSITES

We present a new form of the Josephson junction with dielectric layer containing radioisotopic inclusions. The presence of additional generators of ionization in a semiconducting material (due to α - particles emitted by...

NOVELTIES IN ELECTRICAL MEASUREMENTS AND INSTRUMENTATION<br /> IN THE WAKE OF IMEKO TC4 & TC 19 SYMPOSIA AND ADC WORKSHOP<br /> IN IASI, ROMANIA, SEPTEMBER 2007

From 18 to 22 September 2007, at the Technical University “Gh. Asachi” of Iasi, Romania, there took place undoubtedly important scientific events, held under the auspices of the International Measurement Confederation....

A NEURAL NETWORK BASED SYSTEM FOR SOFT FAULT DIAGNOSIS IN ELECTRONIC CIRCUITS

The paper considers the architecture and the main steps of development of a neural network based system for diagnosis of soft faults in analog electronic circuits. The definition of faults of interest, selection of an op...

APPLICATION OF GENETIC ALGORITHM TO MEASUREMENT SYSTEM CALIBRATION INTENDED FOR DYNAMIC MEASUREMENT

The paper presents an application of the genetic algorithm method for calibration of measurement systems intended for the measurement of dynamic signals. The process of calibration is based on the determination of the ma...

Download PDF file
  • EP ID EP84417
  • DOI -
  • Views 69
  • Downloads 0

How To Cite

ADAM WOŹNIAK (2006). SIMPLE METHOD OF 3D ERROR COMPENSATION OF TRIGGERING PROBES ON COORDINATE MEASURING MACHINE. Metrology and Measurement Systems, 13(3), 289-302. https://europub.co.uk/articles/-A-84417