In this paper the theoretical Break Down Voltage (BDV) is compared with the results obtained from the practical set up results and the results obtained from MATLAB simulation under different size and spacing of the electrodes. Maximum electric field and relative air density factor characteristics are obtained with different temperature and pressure and the effect under all the methods i.e. theoretical, practical and simulation results are compared and plotted for the easy grasp and some salient conclusions for the reliability of the alternate methods and quantum of errors involved are derived to support the version.

Authors and Affiliations

Mr. B. S. Shah, Mr. S. B. Parmar, Mr. J. N. Rathod, Dr. A. S. Pandya

Keywords

Related Articles

Network Load Balancing Using Distributed Algorithm

Network Load Balancing (NLB) is a clustering technology offered by Microsoft as part of all Windows 2000 Server and Windows Server 2003 family operating systems. NLB uses a distributed algorithm to load balance network...

Distributed Java Applications

This paper presents a new Java oriented monitoring infrastructure that enables tools to observe, analyze and manipulate the execution of distributed Java applications independent of implementation details like instrumen...

Implementation of Virtual Synchronous Machine (VSM) Method on Inverters

Virtual Synchronous Machine (VSM) [1] is a control algorithm to make an inverter operated as a conventional electromechanical synchronous machine. It is a promising solution to overcome the problems of the grid stabilit...

Reduction of Common Mode Voltage in Three Level Diode Clamped Inverter

In this paper, an approach to reduce common mode voltage (CMV) at output terminal of the inverter using simple sinusoidal PWM technique is proposed. Multilevel inverter (MLI) is more suitable in high & medium power appl...

DVB-T/T2 Performance in Advanced Mobile TV Channels

The second generation terrestrial standard DVBT2 has a more flexible approach of the system parameters for the mobile and portable digital television broadcasting then DVB-T. This paper deals with the exploring of the D...

Download PDF file
  • EP ID EP18269
  • DOI -
  • Views 287
  • Downloads 14

How To Cite

Mr. B. S. Shah, Mr. S. B. Parmar, Mr. J. N. Rathod, Dr. A. S. Pandya (2014). slugMeasurement of Air Breakdown Voltage and Electric Field Using Standard Sphere Gap Method. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 2(6), -. https://europub.co.uk/articles/-A-18269