Abstract

Introduction: Timely diagnosis and treatment of post-traumatic elevated intracranial pressure (EICP) could be re-duced morbidity and mortality, and improved patients’ outcome. This study is trying to evaluate the diagnostic accu-racy of sonographic optic nerve sheath diameter (ONSD) in detection of EICP. Methods: Sonographic ONSD of pa-tients with head trauma or cerebrovascular accident suspicious for EICP were evaluated by a trained chief resident of emergency medicine, who was blind to the clinical and brain computed tomography scan (BCT) findings of patients. Immediately after ultrasonography, BCT was performed and reported by an expert radiologist without awareness from other results of the patients. Finally, ultrasonographic and BCT findings regarding EICP were compared. To evaluate the ability of sonographic ONSD in predicting the BCT findings and obtain best cut-off level, receiver operat-ing characteristic (ROC) curve were used. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of sonographic ONSD in determin-ing of EICP was calculated. P < 0.05 was considered as statistically significant. Results: There were 222 patients (65.3% male), with mean age of 42.2±19.5 years (range: 16-90 years). BCT showed signs of EICP, in 28 cases (12.6%). The means of the ONSD in the patients with EICP and normal ICP were 5.5 ± 0.56 and 3.93 ± 0.53 mm, re-spectively (P<0.0001). ROC curve demonstrated that the best cut off was 4.85 mm. Sensitivity, specificity, PPV, NPV, PLR, and NLR of ONSD for prediction of EICP were 96.4%, 95.3%, 72.2%, 98.9%, 20.6, and 0.04, respectively. Con-clusion: Sonographic diameter of optic nerve sheath could be considered as an available, accurate, and noninvasive screening tool in determining the elevated intracranial pressure in cases with head trauma or cerebrovascular acci-dent.

Authors and Affiliations

Keywords

Related Articles

Examination of References in Rosen’s Emergency Medicine Text Book, 8th Edition; an Observational Study

Introduction: This study aims to analyze the references that the authors and editors used during the writing of Rosen’s Emergency Medicine, 8th edition. Methods: 15,209 references, which were used in 197 chapters of Ros...

Diagnostic Accuracy of Ultrasonography and Radiography in Detection of Pulmonary Contusion; a Systematic Review and Meta-Analysis

Introduction: Ultrasonography is currently being used as one of the diagnostic modalities in various medical emergencies for screening of trauma patients. The diagnostic value of this modality in detection of traumatic c...

Association of High Serum Adiponectin with the Risk of Malnutrition and Worse Outcome in Head Trauma Patients; a Cohort study

Introduction: A number of studies have shown the association between serum adiponectin level and the nutritional status. This study aimed to evaluate the relation between serum adiponectin and changes in nutritional stat...

Gastrointestinal Headache; a Narrative Review

There are studies reporting primary headaches to be associated with gastrointestinal disorders, and some report resolution of headache following the treatment of the associated gastrointestinal disorder. Headache disorde...

Factors with the Highest Impact on Road Traffic Deaths in Iran; an Ecological Study

Introduction: The largest proportion of road traffic deaths (RTDs) happen in Low and Middle Income Countries (LMICs). The efforts for decreasing RTDs can be successful if there is precise information about its related ri...

Download PDF file
  • EP ID EP318646
  • DOI -
  • Views 289
  • Downloads 0

How To Cite

(2013). Sonographic Optic Nerve Sheath Diameter as a Screening Tool for Detection of Elevated Intracranial Pressure. Archives of Academic Emergency Medicine, 1(1), 15-19. https://europub.co.uk/articles/-A-318646