SPECIFIC MASS FLOW RATE MEASUREMENTS IN A PULSATING FLOW OF GAS

Journal Title: Metrology and Measurement Systems - Year 2008, Vol 15, Issue 2

Abstract

The method of measurement of the specific mass flow rate in a pulsating flow by means of the Constant Temperature Anemometer (CTA) has been described. Special attention has been paid to the probe calibration problem. Different forms of the CTA characteristic have been analyzed. Example measurement results have been presented for chosen pulse frequencies. Apart from the measurements executed in one single point representing each control section, a flow field survey has been done in order to determine the velocity profile under the conditions of a pulsating flow. Probes have been displaced radially with a small step to cover the range from the pipe axis to its wall. It has been found that in the large field around the pipe axis, successive velocity plots are similar as far as their shape and phase shift are considered. Pulsations are damped and mean velocity decreases rapidly only in direct proximity of the pipe wall. It has been also shown that the presence of pulsations makes the mean velocity profile more uniform than in the case of a steady flow. Measurements have been also performed for the case of a reverse flow occurring in the pipe at resonance frequencies.

Authors and Affiliations

ALEKSANDER OLCZYK

Keywords

Related Articles

DIAGNOSIS OF THE OPERATIONAL STATUS OF ELECTROMECHANICAL DEVICES WITH AN OPTICAL FIBER VIBRATION SENSOR

In the presented paper a prototype of an optical fiber vibration sensor is described as a tool for diagnosis of machines and electromechanical devices. The application of the optical fiber as a sensor allowed a design of...

MONITORING OF DRY SLIDING WEAR USING FRACTAL ANALYSIS

Reliable online monitoring of wear remains a challenge to tribology research as well as to the industry. This paper presents a new method for monitoring of dry sliding wear using digital imaging and fractal analysis. Fra...

FREQUENCY-RESPONSE COMPENSATION OF DISTORTING PARTS OF MEASUREMENT SYSTEMS

In this article a class of digital correction filters is presented. This class of filters has been synthesized in an optimization procedure where two criteria are considered. The first criterion is an approximation of th...

CONDUCTANCE QUANTIZATION IN FERROMAGNETIC CO NANOWIRES

Room temperature electronic transport properties of ferromagnetic quantum wires have not been yet fully understood, and the role of electronic structure of magnetic atoms in the conductance quantization is still under di...

MEASUREMENT OF LUMINESCENCE IN COLOURED PRINTED MATERIALS

While fluorescent pigments have been used for many years, the formulation and quality control of coloured printed materials containing them, has been a challenge, primarily due to lack of appropriate instrumentation at a...

Download PDF file
  • EP ID EP144600
  • DOI -
  • Views 74
  • Downloads 0

How To Cite

ALEKSANDER OLCZYK (2008). SPECIFIC MASS FLOW RATE MEASUREMENTS IN A PULSATING FLOW OF GAS. Metrology and Measurement Systems, 15(2), 165-176. https://europub.co.uk/articles/-A-144600