Spectrophotometric Determination of Selenium (IV) Using 4,5-diamino-o-xylene as a New Chromogenic Reagent
Journal Title: Advanced Journal of Chemistry-Section A (Theoretical, Engineering and Applied Chemistry) - Year 2020, Vol 3, Issue 1
Abstract
A simple, rapid, and sensitive spectrophotometric method for the determination of selenium (IV) based on the formation of a 1:2 complex with 4,5-diamino-o-xylene (DAX) as a new sensitive and selective chromogenic reagent is developed. The DAX reacts with selenium (IV) in the presence of citric acid to form a complex in the pH range of 1.0 2.2. The experimental conditions for determining selenium including the influences of pH, reagent concentration and time were evaluated and optimized. Under the optimum experimental conditions, the molar absorptivity of the complex was 1.27×104 L/mol–1 cm–1 at 340 nm. Beer's law is obeyed in the range of 1≃12 µg/mL–1. The limits of detection and quantization were 0.948 µg mL-1 and 3.16 µg/mL-1 respectively. The interfering effect of some cations and anions was also studied. This method can be applied to the direct and easy determination of selenium species as organic, inorganic, Se(VI) and Se(IV) in a variety of real samples.
Authors and Affiliations
Mehdi Tavancheh, Asadollah Beiraghi
Pesticide Residues Detected in Selected Crops, Fish and Soil from Irrigation Sites in the Upper East Region of Ghana
Crops, soil and fish from irrigation farms were investigated in the Upper East Region of Ghana. Questionnaire was administered to collect pesticide use information from farmers, and tomatoes, okro, pepper and garden eggs...
Optimized Rhodium Dissolution Process Using Aqua Regia
The present paper focuses on a unique, optimized process of completely dissolving rhodium that can be employed on a large scale. Dissolution of rhodium has always been a challenging aspect of rhodium metallurgy due to it...
Heat transfer and fluid flow analysis of a novel micro-miniature cryocooler model
In the current study, a new model for micro-scale cooling systems is presented. The small-scale refrigerator is modeled by engraving channels and a micro nozzle on the sides of a rectangular glass. The system has the cap...
Absolute Prediction of the Melting and Freezing Points of Saturated Hydrocarbons Using Their Molar Masses and Atume’s Series
This study was conducted to apply the Atume’s series in the absolute prediction of melting and freezing points of a wide range of saturated liquid and solid hydrocarbons. The calculated results that were obtained, shows...
In Situ Generation of Ammonia: an Efficient Catalyst for the Synthesis of Phenol-Aniline-Formaldehyde Resol Resin
A novel method developed for the synthesis of resol based phenol-aniline-formaldehyde (PAF) resins by in situ generation of ammonia using magnesium hydroxide and ammonium chloride as reagents in the presence of phenol, a...