STATCOM for Compensation of SEIG Feeding Single-Phase and Three-Phase Loads

Abstract

Now-a-days due to the drastically increased in use of nonlinear loads causes many power quality problems in power system network. Those problems are classified as reactive power problems, harmonics, voltage sags and swells. Out of these problems, harmonic problems are a major concern. Custom power devices proposed for mitigation of power quality in network. For compensation of harmonic, static compensator (STATCOM) is used. The paper presents the compensation of harmonic power quality issues using STATCOM for the system with singly-excited induction generator feeding single-phase load and three-phase loads. Proposed concept was developed using MATLAB/SIMULINK software and the results were presented to the system with STATCOM feeding single-phase load and three-phase loads

Authors and Affiliations

Satyanarayana Gorantla, Goli Ravi Kumar

Keywords

Related Articles

Ruthenium Detection By XRF in Metamorphic Rocks

The following report shows the experimental results of detecting Ru (ruthenium) element, in metamorphic rocks, found on different geographic areas of Colombian, performing X-ray fluorescence spectroscopy (XRF). After fie...

The Power System Voltage Stability Analysis Considering Wind Power Generation

Wind control industry is growing extremely expansive so increasingly more wind ranches are assembled and its being associated into the power framework. The wide size of wind control age is likewise increment so sway on s...

Low Cost BLDC Drive Using Single Current Sensor

This paper provides a technique to minimize torque ripple in BLDC motor by using single current sensor. There are number of techniques avail to minimize torque ripple. This paper proposes hysteresis current controller. B...

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

The main aim of this paper is to represents an instantaneous power control of D- STATCOM for power factor and power flow control. When installed DSTATCOM to reduces to power quality disturbance. DSTATCOM device is used f...

DAMPING OF LOW FREQUENCY OSCILLATION USING COORDINATED CONTROL STRATEGY OF PI AND UPFC DEVICES

Rapid growth of Indian economy has stirred a tremendous need for power and has resulted in operation of power infrastructure to their limits. One important impediment in operating the power infrastructure at their maximu...

Download PDF file
  • EP ID EP245002
  • DOI -
  • Views 102
  • Downloads 0

How To Cite

Satyanarayana Gorantla, Goli Ravi Kumar (2017). STATCOM for Compensation of SEIG Feeding Single-Phase and Three-Phase Loads. International Journal of Electrical and Electronics Engineering Research (IJEEER), 7(5), 1-8. https://europub.co.uk/articles/-A-245002