STATISTIC METHODS OF POLYIMIDE ENAMEL ISOLATION DEFECTIVE NON-DESTRUCTIVE CONTROL AT THE CONDITIONS OF PRODUCTION

Abstract

In this paper can be used to not-destructive technological testing of defects isolation enameled wire with polyimide polymer. The thesis is devoted to the statistical method for processing, comparison and analysis of results of measurements of parameters isolation it enameled wire because of mathematical model of trend for application in active technological monitoring is developed; to development used of the recommendations for parameters of such testing. Is theoretically justified and the possibility of a diminution of dependence of an error from a velocity of movement of a wire for want of quantifying of defects enameled isolation not destroying tests by high voltage. This work is devoted to the statistical method for processing, comparison and analysis of results of measurements of parameters of polyimide isolation. The method is operating not destroying technological monitoring an amount of enameled isolation defect. The dependence of average value of amount of defects for enameled wire ПЭЭИДХ2 – 200 with two–sheeted polyimide by isolation in a range of nominal diameter 0.56 mm is experimentally determined. The technological monitoring purpose is reducing of quantifying of enameled isolation defect.

Authors and Affiliations

O. V. Golik, L. A. Shchebeniuk

Keywords

Related Articles

NEURO-SYSTEM OF AIMING AND STABILIZING WITH A REGULATOR ON THE BASIS OF STANDARD MODEL MODEL REFERENCE CONTROLLER

The aim of this work is the synthesis of neural network aiming and stabilization system for the special equipment of moving objects with neuro-controller on the basis of standard model and performance comparison of the n...

DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS

This paper deals with the determination of analytical calculation error of magnetic field of high-voltage cable lines in two-point bonded cable shields caused by non-uniformity of the current distribution in the shields....

AN ANTHOLOGY OF THE DISTINGUISHED ACHIEVEMENTS IN SCIENCE AND TECHNIQUE. PART 41: COMPOSITE MATERIALS: THEIR CLASSIFICATION, TECHNOLOGIES OF MAKING, PROPERTIES AND APPLICATION DOMAINS IN MODERN TECHNIQUE

Purpose. Preparation of brief scientific and technical review about the state, achievements and prospects of development of works domestic and foreign scientists-specialists on materials and technologists in area of deve...

DEVELOPMENT AND INVESTIGATION OF LAYOUT OF ACTIVE SCREENING SYSTEM OF THE MAGNETIC FIELD GENERATED BY GROUP OF OVERHEAD TRANSMISSION LINES

Purpose. Development and field experimental research of layout of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area is given. Metho...

ENERGY LOSS REDUCTION IN SMART GRID UTILITIES FOR ACCOUNT OF TRANSITION FROM SINGLE-PHASE TO THREE-PHASE POWER DISTRIBUTION SYSTEMS

Analytical dependences of such efficiency indices as energy loss power and copper consumption under transition from single-phase power distribution systems to three-phase ones are obtained.

Download PDF file
  • EP ID EP291698
  • DOI 10.20998/2074-272X.2017.1.08
  • Views 90
  • Downloads 0

How To Cite

O. V. Golik, L. A. Shchebeniuk (2017). STATISTIC METHODS OF POLYIMIDE ENAMEL ISOLATION DEFECTIVE NON-DESTRUCTIVE CONTROL AT THE CONDITIONS OF PRODUCTION. Електротехніка і Електромеханіка, 0(1), 47-53. https://europub.co.uk/articles/-A-291698