Abstract

The main objective of the presented paper is to discuss chosen lattice tower joint behavior under structure ultimate load. Joint numerical modelling considerations are enriched with comparison to the full-scale tower pushover test results. Two independent load cases were examined: 1) where the L-sections (diagonal bracings) are loaded by the axial force only and that forces are applied in the center of the member cross section, 2) where the L-sections are loaded by the axial force and the bending moment that reproduce the effect of the eccentric connection to the gusset plates by the one leg of the angle section is added. Differences in equivalent stresses state for two independent design situations allow for conclusion that additional bending moments should be taken into account, especially for thin-walled members.

Authors and Affiliations

Jacek SZAFRAN, Kazimierz RYKALUK

Keywords

Related Articles

Successfull urban regeneration project: Gdańsk-Letnica district case study

This paper presents the process of urban regeneration of Gdansk Letnica district, a project that from a very short time perspective can be described as successful. The paper will present a brief district’s history as wel...

EQUIVALENT STABILIZING FORCE OF THE SIMPLY SUPPORTED ROOF GIRDERS INCLUDING THE LONGITUDINAL VARIABILITY OF THE COMPRESSION FORCE ACTING IN THE RESTRAINED CHORD

In the calculation model of the equivalent stabilizing force qd for bracing system consistent with EN 1993-1-1 it has been conservatively assumed that the member to be restrained is uniformly compressed within its length...

GPS-RTK SIGNAL ANALYSIS CONCEPTION IN APPLICATION TO MONITORING OF ENGINEERING STRUCTURES

The paper presents a concept for analysis of GPS-RTK (Real Time Kinematic) observations in the aspect of monitoring engineering objects, exposed to deformation. It describes the on-line adaptation algorithm for the blind...

Professor Wacław Żenczykowski and undone reform of Poland's housing industry

The American home building program launched after the World War II, resulted with 10 million homes built in 10 years. That enormous success attracted considerable attention from foreign engineers and politicians from all...

EXPERIMENTAL AND NUMERICAL ANALYSIS OF PHOTOVOLTAICS SYSTEM IMPROVEMENTS IN URBAN AREA

Nowadays, photovoltaic systems installed in urban areas have to be an essential part of distributed generation systems, and lead to improve energy efficiency of buildings. The paper describes the operation aspects of the...