STRONG COLUMN WEAK BEAM CONCEPT BY ANALYSING RCC MRF FRAME BY NON LINEAR STATIC PROCEDURE

Journal Title: International Journal of Civil Engineering and Technology - Year 2019, Vol 10, Issue 3

Abstract

During past earthquakes column plastic hinges are more prominent than beam hinges which gives rise to global structural damage and high life threatening risk. All the structural components transfers their forces through column and column than shares it with foundation to soil, so u can imagine if column fails whole structure can collapse this is strong beam weak column concept. By making column more moment resistant than beams the plastic hinges shifts to beam and avoids the global damage in this case only beam will show flexure as a sign of beam damage and the people will have adequate time to evacuate the place and beam failure will only limit to a particular storey. This concept is strong column weak beam. In this paper three RC frame of 5, 8 and 12 storey height are investigated for strong column weak beam concept for zone 5 and medium soil and moment capacities are checked as per IS1893:2016. For checking the performance of plastic hinges of column and beam non linear static analysis (pushover analysis) is done in ETABS 2016 these hinges are checked and verified according to acceptance criteria given in FEMA 356. Base shear and performance point with displacement is checked for all frames.

Authors and Affiliations

AJAY SINGH THAKUR and JAGDISH CHAND

Keywords

Related Articles

PARADIGMS FOR SHAPING URBAN DEVELOPMENT LANDSCAPES IN THE WORLD – A DIAGNOSIS OF THEIR FOCUS AND CHARACTERISTICS

Cities are centers of knowledge and sources of growth and innovation and possess exceptional possibilities for economic development. At the same time, however, the cities undergo certain transformation due to urbanizat...

COMPARATIVE STUDY OF MATERIALS FOR REINFORCEMENT IN BRIDGE PIER BEARINGS

Elastomeric bearings are design efficient and economical, hence widely used in bridge construction worldwide. These bearings need reinforcement to restrict vertical deformation which is generally provided in terms of s...

WATER MANAGEMENT, WATER POLITICS AND RULE OF LAW IN INDIA

The countries around the world which follow constitutional democracy are fully committed to the Rule of law principle, and to the concept of economic, political, social and also environmental justice. This commitment w...

WASTE MANAGEMENT EFFICIENCY IN SEMARANG

In this paper aim is to measure the efficiency of waste management in Semarang, Indonesia. Data Envelopment Analysis (DEA) was used in this study to measure the relative efficiency between Sub-Districts as DMU (Decisio...

MINING OF SEVERAL LONGWALL PANELS WITHOUT RE-INSTALLATION OF EQUIPMENT OF COAL FACE: A CASE STUDY

The main objective of researches was the analysis of experience of application of technological schemes of mining of longwall panels without re-installation of the equipment of a coal face. For conditions of the mine T...

Download PDF file
  • EP ID EP46794
  • DOI -
  • Views 195
  • Downloads 0

How To Cite

AJAY SINGH THAKUR and JAGDISH CHAND (2019). STRONG COLUMN WEAK BEAM CONCEPT BY ANALYSING RCC MRF FRAME BY NON LINEAR STATIC PROCEDURE. International Journal of Civil Engineering and Technology, 10(3), -. https://europub.co.uk/articles/-A-46794