Structural Configuration Optimization of a Multistorey Building by Optimum Positioning of Shear Wall

Journal Title: GRD Journal for Engineering - Year 2016, Vol 1, Issue 0

Abstract

A study has been carried out to determine the optimum Structural configuration of a multistory building by changing the shear wall locations radically. Four different cases of shear wall position for a 10 storey residential building have been analyzed and designed as a space frame system by computer application software, subjected to lateral and gravity loading in accordance with IS provisions.

Authors and Affiliations

Maulik Joshi, Sagar Naik, Yati Tank

Keywords

Related Articles

Hydro Petrol Engine - A Technical Review

Now a day’s energy crises and pollution are major problems. The present investigation is to enhance performance and lower emission characteristics of a single cylinder spark ignition engine operating with hydrogen blends...

Dynamic Analysis of Multi Storied Building with and without Shear Wall and Bracing

Now a day the number of buildings are constructed and designed on the basis of architectural requirement and aesthetic view. Most of buildings are constructed in some spatial configuration like X shape, V shape with x an...

High Efficiency Three Phase Transformer-Less MOSFET Inverter to Drive PMSM Motor

A project proposed a new high efficiency three phase transformer-less photovoltaic (PV) inverter by using super-junction MOSFETs as main power switches. Here fifteen level topologies have been implemented by using H-Brid...

Bio-Activator- As A Solution of Biological Treatment Problems in Dairy Industries

Dairy industries are one of the fastest developing industries of India, but at the same time it is one of the largest amounts of wastewater generating industry, both in case of quality and quantity. Dairy industry has ma...

Mechanical Properties of Pineapple Fibre Reinforced Concrete Subjected to High Temperature

Concrete is one of the most widely used construction material. Apart from its excellent properties, concrete is very poor in tensile strength. In order to improve the tensile properties, fibres are added to the concrete,...

Download PDF file
  • EP ID EP296375
  • DOI -
  • Views 115
  • Downloads 0

How To Cite

Maulik Joshi, Sagar Naik, Yati Tank (2016). Structural Configuration Optimization of a Multistorey Building by Optimum Positioning of Shear Wall. GRD Journal for Engineering, 1(0), 204-208. https://europub.co.uk/articles/-A-296375