Study and Analysis of Insulator used in Substation

Abstract

The main purpose of this paper was that to compare design of post insulators and their performance of different post insulator the relative performance of different insulator materials used in substation as lightning arrester, current transformer and potential transformer. Insulators are used to protect from the dangerous effects of electricity flowing through conductors. This paper presents the role of post insulators are key components of most electrical substation equipment and their features and ability are changing due to the difference type of electrical power incoming line and pollution level of their rating. The peak voltage rating of each arrester at 132 kV is 118.6 kV, creepage distance is 2904 mm and maximum continuous operating voltage is 94.88 kV. The creepage distance of current transformer and potential transformer at 132 kV are 4065 mm. Therefore, in this paper, the effects of material changes, rating changes, pollution level changes of lightning arrester, current transformer and potential transformer in substation are described. Then, analysis and discussion of lightning arrester and instrument transformer are described in this paper. Hnin Yu Lwin | U Hla Myo Htay "Study and Analysis of Insulator used in Substation" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd26574.pdfPaper URL: https://www.ijtsrd.com/engineering/electrical-engineering/26574/study-and-analysis-of-insulator-used-in-substation/hnin-yu-lwin

Authors and Affiliations

Keywords

Related Articles

Multi Objective Optimization of Near-Dry EDM using MOORA-PCA based Taguchi Optimization Method

In any machining operation, the correct and optimized selection of process parameters is the most important aspect. Particularly in Electric Discharge Machining (EDM) also, its process parameters should be optimized to g...

An Efficient OCR System based on the Regional Feature using the ASVM as Classifier

In Image Processing, sometimes due to poor handwriting, the writer left some gap between diacritics and character or between diacritics and header line due to which small text blocks gets created which leads to improper...

A Review on Salesforce

Salesforce is a leading CRM (Customer Relationship Management) software which is served form cloud. It has more than 800 applications to support various features like generating new leads, acquiring new leads, increasing...

Precision Farming

precision mean ”the quality of being clear or exact”. Farmer tries hard to get the result but we need the smart way and result oriented. The history of India's development has been inexorably linked to that of its fa...

Education with Sovereignty and Strength

We have been witnessing number of educational problems everywhere. There are gross violations of fundamental rights, opportunities, weaker person’s rights and injustice etc. There is a lot of mis application of Strength...

Download PDF file
  • EP ID EP628862
  • DOI 10.31142/ijtsrd26574
  • Views 99
  • Downloads 0

How To Cite

(2019). Study and Analysis of Insulator used in Substation. International Journal of Trend in Scientific Research and Development, 3(5), 1160-1163. https://europub.co.uk/articles/-A-628862