Study of approaches to incipient fault detection in power transformer by using dissolved gas analysis

Journal Title: Energetika - Year 2017, Vol 0, Issue 0

Abstract

To maintain the reliability of power transmission it is important to detect the incipient fault of power transformer as early as possible. If the fault of a power transformer is not detected promptly, it can evolve resulting in high repair costs or even failure of the power transformer and decreasing reliability of power transmission. The most commonly used method for power transformer fault detection is the dissolved gas analysis (DGA) of transformer oil. Various methods have been developed to interpret the data of dissolved gas analysis, but not many are applicable for the detection of the incipient fault. The detection of the incipient fault of a power transformer is included in both IEEE C57.104-2008 “Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers” and Standard of Latvian Electrotechnical Committee LEK 118 “Transformer Oil Inspection Standards”. In both standards, the limits of dissolved gases in transformer oil are divided into levels, each corresponding to different technical conditions of the power transformer including the level that indicates the incipient fault. However, these approaches vary to a great degree – one approach mostly indicates that transformers are in good condition with several cases that must be additionally evaluated, but the second approach mostly results in warning about the incipient fault, which must be confirmed by additional evaluation. The objective of this paper is to determine the most suitable approach to detect the incipient fault of power transformers. A case study is provided, which includes analysis of DGA data of 48 power transformers installed in the transmission network in Latvia with both methodologies mentioned above for detecting the incipient fault.

Authors and Affiliations

Ruta Liepniece, Sandra Vitolina, Janis Marks

Keywords

Related Articles

Cybersecurity of critical infrastructures such as nuclear facilities

In the last years, cybersecurity has become a crucial essential element within the security framework of critical infrastructures such as process industry, railways, hospitals and also nuclear facilities. The types of th...

A comparative study on physical properties of Al-doped zinc oxide thin films deposited from zinc acetate and zinc acetylacetonate by spray pyrolysis

Herein we present a comparative study on highly transparent, conductive aluminium-doped ZnO (AZO) thin films deposited by pneumatic spray pyrolysis (PSP) of a zinc acetate based solution and a zinc acetylacetonate based...

Advanced exergetic analysis of a heat pump providing space heating in built environment

In addition to conventional exergy-based methods, advanced exergetic analyses consider the interactions among components of the energy-conversion system and the real potential for improving each system component. The pap...

Monte Carlo simulation of district heating system short-term operation in electricity markets

Energy generation in district heating (DH) systems is usually done in combined heat and power (CHP) units which can efficiently produce both useful heat and electric power. There can also exist heat only boilers, electri...

Already the 15th Conference of Young Scientists on Energy Issues (CYSENI) at Lithuanian Energy Institute

Believe it or not, but the first steps of the conference of young scientists of Lithuanian Energy Institute (LEI) were done long time ago – back in 2002. It was based on the idea of having our own plat...

Download PDF file
  • EP ID EP260796
  • DOI 10.6001/energetika.v63i2.3521
  • Views 83
  • Downloads 0

How To Cite

Ruta Liepniece, Sandra Vitolina, Janis Marks (2017). Study of approaches to incipient fault detection in power transformer by using dissolved gas analysis. Energetika, 0(0), 66-74. https://europub.co.uk/articles/-A-260796