STUDY OF THE MAGNETIC FIELD OF THREE PHASE LINES OF SINGLE CORE POWER CABLES WITH TWO-END BONDING OF THEIR SHIELDS

Abstract

The study tested the process of the magnetic field (MF) mitigation in the HV three-phase power cable lines (CL) made of single core cables in two-ends bonding of their shields. Developed the technique of numerical simulation and calculation of the MF of CL based on its axisymmetric calculation model using the finite element method that allowed to describe the condition of closing the cable shields at the both ends of the CL and solve the problem in two-dimensional formulation. The authors show the possibility of MF mitigation of the three-phase CL by increasing the cross-section of closed cable shields, which in some cases may be an alternative to external electromagnetic shields. Obtained and experimentally validated in laboratory and field conditions with an accuracy of no more than 5 % the value of mitigation coefficients of MF of three-phase three-wire CL in two-ends bonding of their shields depending on the technical parameters of the cables and the geometry of their installation, which is important for the design of new cable power lines. Their values are in the range from 0.99 to 0.32 when the cross sections of cable shields are from 25 mm2 to 200 mm2 and the distance between the axes of the cables are from 0.1 to 0.5 m. The results show the ability to execute design of cable power lines in residential areas, taking into account both the sanitary standards of the MF, as well as to energy efficiency.

Authors and Affiliations

V. Yu. Rozov, A. A. Kvytsynskyi, P. N. Dobrodeyev, V. S. Grinchenko, A. V. Erisov, A. O. Tkachenko

Keywords

Related Articles

INVESTIGATION AND CALCULATION OF VALLEYS OF OUTGOING FROM SUBSTATION GROUNDING CONDUCTORS FOR SHORT-CIRCUIT IN SINGLE-PHASE SHORT OF ELECTRICAL GRID

Introduction. Earthing device electrical substation in modern conditions must meet both the requirements of electrical safety of people and animals, as well as electromagnetic compatibility requirements established her e...

SINGLE-CIRCUIT ACTIVE SCREENING OF MAGNETIC FIELD GENERATED BY SEVERAL OVERHEAD TRANSMISSION LINES IN RESIDENTIAL AREA

Purpose. The synthesis of active screening system of magnetic field, generated by several high voltage overhead transmission lines, with the help of single compensation cables is presented. Methodology. The initial param...

THE DIAGNOSTICS OF INDUCTION MOTORS ROTOR BAR BREAKS BASED ON THE ANALYSIS OF ELECTROMOTIVE FORCE IN THE STATOR WINDINGS

A method for diagnostics of the induction motor rotor bar breaks, based on the wavelet-analysis of the electromotive force induced in the stator windings in the rundown mode is developed. A method for decomposition of th...

METHODOLOGY OF DETERMINATION OF QUALITY INDEX OF MAINTENANCE SERVICE SYSTEM OF POWER EQUIPMENT OF TRACTION SUBSTATIONS

Purpose. The purpose of this paper is development of methodology for definition of a quality system of maintenance and repair (M and P) power equipment of traction substations (TS) of electrified railways operating under...

THE THYRISTOR CONVERTER INFLUENCE ON THE PULSATIONS OF THE ELECTROMAGNETIC TORQUE OF THE INDUCTION MOTOR AT PARAMETRICAL CONTROL

Purpose. The purpose of the work is to identify the parameters influence of the electric motor, the power circuits elements of the converters, built on resistor-thyristor modules, the static torque and the moment of iner...

Download PDF file
  • EP ID EP301324
  • DOI 10.20998/2074-272X.2015.4.11
  • Views 52
  • Downloads 0

How To Cite

V. Yu. Rozov, A. A. Kvytsynskyi, P. N. Dobrodeyev, V. S. Grinchenko, A. V. Erisov, A. O. Tkachenko (2015). STUDY OF THE MAGNETIC FIELD OF THREE PHASE LINES OF SINGLE CORE POWER CABLES WITH TWO-END BONDING OF THEIR SHIELDS. Електротехніка і Електромеханіка, 0(4), 56-61. https://europub.co.uk/articles/-A-301324