STUDY OF THE MAGNETIC FIELD OF THREE PHASE LINES OF SINGLE CORE POWER CABLES WITH TWO-END BONDING OF THEIR SHIELDS

Abstract

The study tested the process of the magnetic field (MF) mitigation in the HV three-phase power cable lines (CL) made of single core cables in two-ends bonding of their shields. Developed the technique of numerical simulation and calculation of the MF of CL based on its axisymmetric calculation model using the finite element method that allowed to describe the condition of closing the cable shields at the both ends of the CL and solve the problem in two-dimensional formulation. The authors show the possibility of MF mitigation of the three-phase CL by increasing the cross-section of closed cable shields, which in some cases may be an alternative to external electromagnetic shields. Obtained and experimentally validated in laboratory and field conditions with an accuracy of no more than 5 % the value of mitigation coefficients of MF of three-phase three-wire CL in two-ends bonding of their shields depending on the technical parameters of the cables and the geometry of their installation, which is important for the design of new cable power lines. Their values are in the range from 0.99 to 0.32 when the cross sections of cable shields are from 25 mm2 to 200 mm2 and the distance between the axes of the cables are from 0.1 to 0.5 m. The results show the ability to execute design of cable power lines in residential areas, taking into account both the sanitary standards of the MF, as well as to energy efficiency.

Authors and Affiliations

V. Yu. Rozov, A. A. Kvytsynskyi, P. N. Dobrodeyev, V. S. Grinchenko, A. V. Erisov, A. O. Tkachenko

Keywords

Related Articles

RESEARCH ON ADDED INDUCTANCE AND RESISTANCE DURING SPIRAL FERROMAGNETIC WIRE SCANNING WITH MAGNETIC FIELD OF A PARAMETRIC EDDY-CURRENT SENSOR

Criteria for estimation of added inductance and resistance during spiral ferromagnetic wire scanning of single-core power cable armour by means of a parametric electromagnetic converter are proposed. Research into variat...

SYNTHESIS OF AN ACTIVE SHIELDING SYSTEM OF THE MAGNETIC FIELD OF POWER LINES BASED ON MULTIOBJECTIVE OPTIMIZATION

Purpose. The synthesis of the active shielding systems by technogenic magnetic field generated by the different types of high voltage power lines in a given region of space using various cables of controlled magnetic fie...

METHODOLOGY OF DETERMINATION OF QUALITY INDEX OF MAINTENANCE SERVICE SYSTEM OF POWER EQUIPMENT OF TRACTION SUBSTATIONS

Purpose. The purpose of this paper is development of methodology for definition of a quality system of maintenance and repair (M and P) power equipment of traction substations (TS) of electrified railways operating under...

AN ACTIVE POWER FILTER AT OPERATION ON THE UNBALANCED AND NONLINEAR LOADS WITH CONTROL BY OPTIMIZATION ALGORITHM

Purpose is to develop a method for controlling a power active filter based on search optimization using software of Mathlab package and applying this method for balancing and compensating for all components of reactive p...

NUMERICAL FIELD ESTIMATION OF TURBOGENERATOR STATOR WINDING SHORTENING EFFICIENCY

On the basis of numerical calculations of rotating magnetic field, a turbogenerator is evaluated for cases of a shortened stator winding and a diametric one. The parameters compared are the shape and harmonic composition...

Download PDF file
  • EP ID EP301324
  • DOI 10.20998/2074-272X.2015.4.11
  • Views 65
  • Downloads 0

How To Cite

V. Yu. Rozov, A. A. Kvytsynskyi, P. N. Dobrodeyev, V. S. Grinchenko, A. V. Erisov, A. O. Tkachenko (2015). STUDY OF THE MAGNETIC FIELD OF THREE PHASE LINES OF SINGLE CORE POWER CABLES WITH TWO-END BONDING OF THEIR SHIELDS. Електротехніка і Електромеханіка, 0(4), 56-61. https://europub.co.uk/articles/-A-301324