Survey of Patients Radiation Doses in Computed Tomography Chest Imaging: Proposal of Diagnostic Reference Level
Journal Title: Scholars Journal of Applied Medical Sciences - Year 2015, Vol 3, Issue 2
Abstract
Advances in CT system technology have improved the diagnosis of many clinical conditions and consequence new investigation methods emerged. However, CT procedures expose the patients to high an avoidable radiation doses which may increase the individuals lifetime radiation risk of developing cancer. This study was intended to evaluate patient doses during chest CT procedures in a certain radiological hospitals in order to establish a local diagnostic reference level (DRL). A total of 78 CT chest procedures were performed during one year. The range of patient dose per CT procedure was 126.0 mGy.cm to 1104.0 mGy.cm per chest procedure. The CTDIvol ranged between 3.0 mGy to 20 mGy per procedure. Patient dose variation attributed to CT modality and image acquisition protocol. Patients exposed to a higher radiation doses in 64 slices compared to other two modalities due to the use of sequential technique at the later one. Diagnostic reference level was proposed for chest CT procedures. Keywords: Chest imaging, Radiation dose, Medical exposure, DRL, Computed tomography.
Authors and Affiliations
Mohamed Yousef, Abdelrahman M. Elnour, Hiba Omer, Abdelmoneim Sulieman
Psychopathology of the Children Suffering from Chronic Illnesses due to Thalassemia Major and Nephrotic Syndrome
Abstract: A descriptive observational study of cross sectional design was undertaken for children suffering from thalassemia major and nephrotic syndrome to evaluate the psychopathology amongst them. Each group comprisin...
A Comparative Study of Isosorbide Mononitrate and Dinoprostone Gel for Cervical Ripening At Term
Abstract: The aim of the study is to compare Isosorbide Mononitrate and Dinoprostone gel for cervical ripening in terms of efficacy and safety. In this study 220 pregnant women attending the antenatal clinics were evalua...
Request for Temporary Contraception at University of Calabar Teaching Hospital (UCTH), Calabar, Nigeria: Why the Preference for Cooper T IUD?
The intrauterine devices (IUD) are widely used contraceptive methods all over the world. They are cheap, durable and very effective. This is a retrospective study directed at evaluating the request for temporary contrace...
A study of pattern and causes of anemia in elderly patients admitted at tertiary centre
Abstract: Anemia in the elderly is common and increasing as the population ages. In older patients, anemia of any degree contributes significantly to morbidity and mortality and has a significant effect on the quality of...
Knowledge and Practice of Nursing Students on Health Care Ethics
Abstract: The nursing students are responsible for gaining knowledge about health care ethics and all nursing institutions or colleges either in worldwide or in Malaysia made ethics, moral and laws are included in their...