SYSTEM FOR DIAGNOSTICS AND PROTECTION AGAINST EARTH FAULTS OF CABLE AND OVERHEAD LINES 6-35 kV

Journal Title: Machinery and Energetics - Year 2018, Vol 0, Issue 283

Abstract

The development of distributed generation, including wind power, requires an increase in the reliability of the operation of cable lines with a voltage of up to 35 kV, which are used to concentrate electrical energy from individual generators. In the construction of wind farms continues to operate rural air lines of the same voltage class. Timely detection of the occurrence of defects in the insulation of power lines will eliminate the causes of short circuits and emergency shutdowns. The aim of the work is the development of a microprocessor device for diagnosing the state of insulation and protection against single-phase earth faults of transmission lines. The principle of operation of the device is based on monitoring the values of the zero sequence currents with the help of cable zero-sequence current transformers. To provide high sensitivity to low values of currents that arise when insulation defects appear, it is proposed to use additional magnetomotive force in current transformers with a frequency that differs from the industrial one. Due to this, the operating point passes to the steeper section of the characteristic. The scheme of the device based on industrial microprocessor protection is proposed. The microprocessor system of determination of phase closures on the ground and defects of isolation in operating modes of cable and air (with a cable insert for a zero sequence transformer) of electric power lines, the principle of which is based on the control of zero currents, is proposed. In the proposed system, increasing sensitivity to known protections is ensured by the use in the cable transformer of a zero-sequence current of an additional magneto-driving force, the frequency of which differs from the industrial frequency. The device passed laboratory and industrial tests and is recommended for implementation.

Authors and Affiliations

М. В. ГРЕБЧЕНКО, О. В. КОЖУХАР

Keywords

Related Articles

PROBABILITY OF PREVENTING LOSS OF EFFICIENCY OF AGRICULTURAL MACHINERY DURING EXPLOITATION

Ensuring availability of agricultural machinery in the process of exploitation is a complex and important task that needs financial support, timely and rational implementation of complex of measures, in most cases, the s...

INVESTIGATION OF ELECTROMAGNETIC PROCESSES OF THE ELECTRON KEY SNUBERN UNIT VOLTAGE REGULATOR

Introduction. For a regulated asynchronous electric drive, semiconductor voltage converters, in particular thyristor regulators, are often used, for which technical literature does not pay much attention to the study of...

ОПТИМІЗАЦІЯ РЕЖИМУ РЕВЕРСУВАННЯ РОЛИКОВОЇ ФОРМУВАЛЬНОЇ УСТАНОВКИ ЗА ПРИСКОРЕННЯМ ЧЕТВЕРТОГО ПОРЯДКУ

З метою підвищення надійності та довговічності роликової формувальної установки розраховано оптимальний режим зворотно-поступального руху формувального візка з реверсуванням за прискоренням четвертого порядку. Розрахован...

ДИСКРЕТНО-КОНТИНУАЛЬНА МОДЕЛЬ РУХУ СТРІЧКОВОГО КОНВЕЄРУ

Наведена дискретно-континуальна модель руху стрічкового конвеєру. Хвилеутворення, які виникають у стрічці конвеєру, що транспортує вантаж, розглянуті з позиції динаміки системи з розподіленими параметрами. Використані ме...

ОСОБЛИВОСТІ ДОСЛІДЖЕННЯ МІЦНОСТІ ЗЧЕПЛЕННЯ КОМПОЗИЦІЙНИХ КОНТАКТНИХ МАТЕРІАЛІВ ЗІ ЗНОШЕНИМИ ДЕТАЛЯМИ ЕЛЕКТРООБЛАДНАННЯ

Розглянуто питання дослідження контактних матеріалів за відновлення контактних вузлів електричних апаратів на твердість, утомленість та проникність.

Download PDF file
  • EP ID EP388509
  • DOI -
  • Views 67
  • Downloads 0

How To Cite

М. В. ГРЕБЧЕНКО, О. В. КОЖУХАР (2018). SYSTEM FOR DIAGNOSTICS AND PROTECTION AGAINST EARTH FAULTS OF CABLE AND OVERHEAD LINES 6-35 kV. Machinery and Energetics, 0(283), 67-75. https://europub.co.uk/articles/-A-388509