Abstract

The individual and environmental passive monitoring program of the Extreme Light Infrastructure - Nuclear Physics (ELI-NP) will use a combination of Optically Stimulated Luminescence (OSL) and Solid State Nuclear Track Detector – (SSNTD) detectors. The OSL dosimeters are dedicated for X-rays/gamma radiation monitoring and will contain BeO detectors which provide the personal dose equivalent and the ambient dose equivalent or the directional dose equivalent according to SR EN 62387-1:2012. The SSNTDs are from poly-allyl diglycol carbonate (CR39), whose performance and test requirements are conform to the criteria of ISO 21909-1:2015 and ISO 8529-3:1998 standards. All the activities of the Radiation Dosimetry Laboratory from ELI-NP will comply the requirements of the ISO/IEC 17025:2005 standard. This paper presents the management of the technical aspects of Quality Management System (QMS) implemented in the Radiation Dosimetry Laboratory ELI-NP facility, Romania. The accuracy and reliability of laboratory tests are determined by factors such as human factors; accommodation and environmental conditions; methods of analyzing and validating methods; used equipment; traceability of the measurement; sampling; manipulation of measurement items. All of the factors above will contribute to total measurement uncertainty. For this purpose an important role it has the effective management of the technical aspects of the QMS.

Authors and Affiliations

Dorina ARANGHEL, Doina STANCIU, Chivuta-Ramona BADITA, Ana STOCHIOIU, Ion TUDOR

Keywords

Related Articles

Shell Closure N = 82 nuclei interpretation by the Cranked Nilsson-Strutinsky Model : 136-138Ce

A theoretical studying of nuclei in the shell closure region (N =82), in particular cerium isotopes 136-138Ce, has been made in the frame of macroscopic-microscopic, Cranked Nilsson Strutinsky (CNS)model. Many n...

Surface Energy Coefficient Determination in Global Mass Formula from Fission Barrier Energy

Semi-empirical mass formulae of the atomic nucleus describe binding energies of the nuclei. In the simple configuration and pattern of this formula, there are five terms related to the properties of the nuclear structure...

Evaluation of Kinetic Effects of Baicalein in Different Breast Cancer Cell Lines

The aim of this study was to compare the antiproliferative effects of baicalein which is a flavonoide on MCF-7 and MDA-MB-231 cell line. The experiments were carried out with the evaluation of the parameters. Including c...

Solution of Vector Equation of Transfer in a Finite Plane Parallel Media

HN method is used for the solution of vector equation of transfer, which includes two Stokes parameters, with a combination of Rayleigh and isotropic scattering in a finite plane-parallel atmosphere. The behavior of albe...

Çoklu-İlaç Dirençli P. aeruginosa ve E.coli Suşlarında Antibiyotik Direnç Genlerinin ve Sınıf 1 İntegron Gen Kasetlerinin Araştırılması

P. aeruginosa ve E.coli izolatlarının birçok antibiyotiğe direnç kazanması nedeniyle bu patojenlerin neden olduğu enfeksiyonların tedavisi zorlaşmıştır. Bundan dolayı klinik izolatlarda antibiyotik direnç genlerinin beli...

Download PDF file
  • EP ID EP488475
  • DOI 10.17776/csj.363633
  • Views 50
  • Downloads 0

How To Cite

Dorina ARANGHEL, Doina STANCIU, Chivuta-Ramona BADITA, Ana STOCHIOIU, Ion TUDOR (2018). Technical Aspects of the Quality Management System (QMS) for the Radiation Dosimetry Laboratory at ELI-NP Facility. Cumhuriyet Science journal, 39(1), 80-86. https://europub.co.uk/articles/-A-488475