Tensile Strength of Novel Experimental Hydrophilic Vinyl Polysiloxane Impression MaterialsCompared to Control and Commercial VPS Impression Materials

Journal Title: Journal of Islamabad Medical and Dental College - Year 2018, Vol 7, Issue 1

Abstract

Objective:To measure the tensile strength of novel experimental hydrophilic (medium bodied) vinyl polysiloxane impression materials developed from ab initio in comparison to control and commercial vinyl polysiloxane impression materials.Materialsand Methods:This experimental study was conducted atthe Department of Oral Growth and Development, Bart’s and The London School of Medicine and Dentistry, Queen Mary, University of London, UK from 1stOct 2010 to 28thFebruary 2014. Five novel experimental (medium bodied) VPS impression materials (Exp-I, II, III, IV and V) were developed and evaluated for their effect as crosslinking agent and surfactant on the tensile strength and percent elongation-at-break in comparison to control and three commonly used commercial (medium bodied) VPS impression materials (Aquasil Ultra Monophase, EliteHD Monophase, Extrude. These properties were evaluated using Tenius Olsen (mechanical testing machine).Results:Aquasil Ultra Monophase (Aq M) had a significantly higher Ultimate Tensile Strength (UTS) compared to all commercial and Experimental VPS. Although Exp-III showed the lowest UTS among all the materials but this was only significant for Aq M. On comparing Exp-I (control) with Exp-II, after adding TFDMSOS into Exp-II there was a slight, but not significant, increase in UTS. After adding the surfactant to hydrophilic Exp-III, IV and V, the UTS decreased slightly, but not significantly, compared to Exp-II. After addition of cross-linking agent (TFDMSOS) there was a significant increase in elongation-at-break of Exp-II compared to the control (Exp-I),which was further significantly increased after incorporating the surfactant (Rhodasurf CET-2) in the Exp hydrophilic VPS formulations (Exp-III, IV and V). Elongation-at-break was significantly increased after incorporating the surfactant (Rhodasurf CET-2) in the Exp hydrophilic VPS formulations (Exp-III, IV and V) compared to Exp-II.Conclusion: All Exp VPS had significantly higher % elongation-at-break (more than double) than commercial VPS. Percentage elongation-at-break further increased significantly after adding Rhodasurf CET-2 (Surfactant)

Authors and Affiliations

Sadaf Humayoun

Keywords

Related Articles

omparison of Peritonsillar Injection of Lignocaine-Adrenaline and Normal Saline (placebo) Before Tonsillectomy in Terms of Mean Per-Operative Blood Loss

Objective:To compare peritonsillar injection of lignocaine-adrenaline and normal saline (placebo) before tonsillectomy in terms of mean peroperative blood loss.Patientsand Methods:This randomized controlled trial was car...

Efficacy of Spot Urinary Albumin Excretion Test for the Detection of Early Nephropathy

Objective: To compare the effectiveness of spot urinary microalbumin excretion for detection of early diabetic nephropathy in comparison with 24 hours urinary proteins in patients with diabetes mellitus. Materials and Me...

Laparoscopy Versus Laparotomy in the Management of Ectopic Pregnancy

Objective:To compare the outcome of laparoscopy with laparotomy in the management of ectopic pregnancy (EP), both ruptured and un-ruptured.Patientsand Methods:This cross-sectional study was conducted...

Spontaneous Bacterial Peritonitis and its Common Pathogens in HCV Cirrhotic Patients

Objective:To determine the spontaneous bacterial peritonitis and its common pathogens in HCV Cirrhotic patients.Patientsand Methods:This cross-sectional descriptive study was conducted at department of Medicine...

Efficacy of the Epidural Blood Patch for the Treatment of Post Epidural Puncture Headache

Objective:To evaluate the efficacy of the epidural blood patch for the treatment of post-Dural puncture headache (PDPH).Patientsand Methods:This cross sectional study was conducted in the Department of Anest...

Download PDF file
  • EP ID EP598501
  • DOI -
  • Views 150
  • Downloads 0

How To Cite

Sadaf Humayoun (2018). Tensile Strength of Novel Experimental Hydrophilic Vinyl Polysiloxane Impression MaterialsCompared to Control and Commercial VPS Impression Materials. Journal of Islamabad Medical and Dental College, 7(1), 69-72. https://europub.co.uk/articles/-A-598501