Test Bed Installation for Performance Evaluation of Radon Mitigating Materials

Abstract

Radon is a naturally occurring radioactive gas. It originates from the decay of uranium, which is present in small quantities in all rocks and soils. It is colorless, odorless and tasteless and can only be measured using special equipment. Because it is a gas, radon can move freely through the soil enabling it to enter the atmosphere. In this paper, we install the test bed for performance evaluation of radon reduction of a SGM and an ARM. The test bed was set in a concrete structure which consists of eight partitioned rooms. The bottom side of each room is covered by radon gas soil sampled at nearby open fields. Then, we install SGMs and ARMs on top of the soil to protect the indoor air. Gyu-Sik Kim | Yong Cheol Kim | Young Sub Lee | Yong Hee Lee"Test Bed Installation for Performance Evaluation of Radon Mitigating Materials" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-3 , April 2018, URL: http://www.ijtsrd.com/papers/ijtsrd11550.pdf http://www.ijtsrd.com/engineering/electrical-engineering/11550/test-bed-installation-for-performance-evaluation-of-radon-mitigating-materials/gyu-sik-kim

Authors and Affiliations

Keywords

Related Articles

Fabrication and Study of the Mechanical Properties of AA7129 Alloy Reinforced with B4C andTiC

In the present work Al7129 metal matrix reinforced with Titanium carbide TiC and Boron carbide B4C powder is fabricated through stir casting route. Metal matrix composites were manufactured by altering percent weight fra...

Assessment of Physico Chemical Characteristics of Groundwater Quality of Ajmer City in Rajasthan

Studies of Physico chemical parameters of groundwater quality based on Physico chemical parameters of Ajmer city in Rajasthan have been taken up to evaluate its suitability for domestics purpose. 21 ground water samples...

Effect of Financial Reporting Quality on Corporate Performance Evidence from Listed Banks in Nigeria

This study determined the relationship between discretionary accruals, non discretionary accruals, on return on investment. Data for this study were obtained from secondary sources only. The study adopted an ex post fact...

Review on Earth Observation and Space Museum Application

In recent years, Earth Observation has become technologically increasingly sophisticated. It has also become more important due to the dramatic impact that modern human civilization is having on the planet Earth, and the...

Improving Analog Performance and Suppression of Subthreshold Swing using Hetero-Junction Less Double Gate Tunnel FETs

In this paper, we investigated a new device, Hetero-junction less (H-JL) Double Gate Tunnel Field Effect Transistors (DGTFET) with high-k. III-V semiconductor material (like InAs-Si) gives excellent performance when InAs...

Download PDF file
  • EP ID EP360392
  • DOI -
  • Views 46
  • Downloads 0

How To Cite

(2018). Test Bed Installation for Performance Evaluation of Radon Mitigating Materials. International Journal of Trend in Scientific Research and Development, 2(3), -. https://europub.co.uk/articles/-A-360392