Testing Solutions of the Protection Systems Provided with Delay Maximum Current Relays
Journal Title: Carpathian Journal of Electrical Engineering - Year 2017, Vol 11, Issue 1
Abstract
Relay protection is one of the main forms of automation control of electro energy systems, having as primary aims fault detection and disconnection of the faulty element in order to avoid the extent of damages and the as fast as possible recovery to the normal operation regime for the rest of the system. Faults that occur in the electro energy system can be classified considering on one hand their causes and on the other their types, but in the vast majority of cases the causes of the faults are combined. Further, considering their nature, faults are classified in faults due to the insulation’s damage, in faults due to the destruction of the integrity of the circuits and faults determined by interruptions. With respect to their nature, faults are short circuits, earthing faults and phases interruptions. At the same time, considering their type, faults are divided in transversal and longitudinal ones. The paper presents a testing solution of the delayed maximal current relays using a T3000 ISA Test measuring equipment.
Authors and Affiliations
Horia Balan, Mircea Buzdugan, Ionut Iancau, Liviu Neamt
Image Steganograpfhy Tailored to Objects Contours
This article proposes a steganography method that uses all three components of an image in the RGB color space to store secret data. The order in which the image pixels are processed is not given by their position within...
Investigation of Electrical Energy Efficiency Use in an Automobile Assembly Industry
This research work investigated the electrical energy efficiency improvement and cost saving potentials for automobile assembly plant; a case of Peugeot Automobile Nigeria Limited. The study identified lighting system as...
Comparison of Various Epson Smart Glasses in Terms of Real Functionality and Capabilities
The article presents some experiences with the smart glasses developed by Epson, namely Movrio BT-200, BT-300 and BT-2000. We conclude that they are on the right track, good devices, however, are still in an incipient, b...
The Reduction of Total Harmonic Distortion for the Multilevel Converter Using Genetic Algorithms Optimization Method
Electricity, DC voltage – AC voltage, conversion generated from certain renewable energy sources such as photovoltaic panels should be made with quality factors imposed by the present standards. In the case of multilevel...
Biot-Savart Law Application in Wireless Power Transfer – Dependence of Magnetic Field to Angle Position
The magnetic field of a closed loop of conductive wire can be computed due to Biot-Savart law, which analyses the value of the field at an exterior point from the transversal axis. If the measure point is out of the axis...