THE ABSORPTION CHARACTERISTICS OF THE PHASE AND ZONE PAPER-IMPREGNATED INSULATION OF POWER CABLE AT DIRECT VOLTAGE

Abstract

Introduction. The moral and physical deterioration of medium voltage power cables with phase and zone paper-impregnated insulation requires implementation of quality systems and reliable nondestructive electric diagnostic. Informative indicator of the insulation is the time decay curve of the charging current. It reflects the processes of accumulation of space charges (absorption). The measurements are carried out the 15th since the second direct voltage supply, then – on the 30th and the second on the 60th second. The ratio of the parameters measured in these times gives the dimensionless criteria – absorption coefficients. Three measurements are made at different times, provide a more complete picture of the state of insulation than the measurement of the value of steady leakage (conduction-through), adopted in conventional prevention trials. Purpose. Research and testing methods of diagnostics of power cables with paper-impregnated insulation by absorption and phase characteristics of the belt insulation based on the total measurements. Methodology. A procedure for determining the individual characteristics of phase and zone paper-impregnated insulation based realized on the use of the equivalent circuit of a three-core cable in the metal shell and solved of an over determined system of linear algebraic equations by least squares. Results. The proposed method allows determining the absorption characteristics of the individual phase and zone insulation medium voltage power cables in the overall metal shell at a direct voltage. Individual characteristics reflect the characteristics of cables and allow a greater degree to assess the degree of aging of each of the components of paper-impregnated insulation. Originality. Regardless of the cable connection diagrams probing electric field grabs as the phase, and zone insulation. The cumulative nature of the measurement leads to the fact that the differences in the properties of insulation components are smoothed: the aggregate results of the measurements do not differ for the different schemes of the same type. The individual characteristics of isolation, defined on the basis of the proposed method are more differences than total, indicating that non-symmetrical modes of operation of the cable. Practical value. The values of individual characteristics power cables 6 kV are 3 times more total, because of what their direct measurement may be a problem. The total resistance of several insulation spaces connected in parallel, behind the individual. Smaller values of insulation resistance are measured more easily, especially on short samples cables.

Authors and Affiliations

G. V. Bezprozvannych, E. S. Moskvitin, A. G. Kyessaeyv

Keywords

Related Articles

ELECTRIC GENERATOR IN THE RECUPERATION SYSTEM OF THE ENERGY FROM MECHANICAL OSCILLATIONS IN VEHICLES

The paper deals with the system of mechanical energy recuperation of vehicles in the useful electric energy accumulated in the rechargeable battery. This system creates an additional power supply on board of the vehicle...

THE ABSORPTION CHARACTERISTICS OF THE PHASE AND ZONE PAPER-IMPREGNATED INSULATION OF POWER CABLE AT DIRECT VOLTAGE

Introduction. The moral and physical deterioration of medium voltage power cables with phase and zone paper-impregnated insulation requires implementation of quality systems and reliable nondestructive electric diagnosti...

METHODICS, SOFTWARE AND LABORATORY EQUIPMENT FOR AN INNOVATIVE ELECTRICAL ENGINEERING DISCIPLINE

Purpose. Development of innovative electrical engineering discipline «Electric Machines in Mechatronic Systems» in order to improve the training of specialists of electrical engineering specialty. Methodology. The propos...

DETERMINATION OF INSULATION PARAMETERS OF CURRENT TRANSFORMERS AT MULTIPLE MEASUREMENTS IN MONITORING SYSTEMS UNDER WORKING VOLTAGE

Features of the data processing procedures of multiple measurements of the dielectric loss tangent of the high-voltage insulation, which are based on the comparison method, were considered. Three procedures were compared...

OPTIMAL UTILIZATION OF ELECTRICAL ENERGY FROM POWER PLANTS BASED ON FINAL ENERGY CONSUMPTION USING GRAVITATIONAL SEARCH ALGORITHM

Purpose. Energy consumption is a standard measure to evaluate the progress and quality of life in a country. When used properly and logically it could be cause of progress in science, technology and welfare of the people...

Download PDF file
  • EP ID EP298271
  • DOI 10.20998/2074-272X.2015.5.09
  • Views 90
  • Downloads 0

How To Cite

G. V. Bezprozvannych, E. S. Moskvitin, A. G. Kyessaeyv (2015). THE ABSORPTION CHARACTERISTICS OF THE PHASE AND ZONE PAPER-IMPREGNATED INSULATION OF POWER CABLE AT DIRECT VOLTAGE. Електротехніка і Електромеханіка, 0(5), 63-68. https://europub.co.uk/articles/-A-298271