THE ANALYSIS OF DYNAMIC RESPONSE AND VOLTAGE FLICKER WITH STATCOM ON DISTRIBUTION NETWORK

Abstract

The Flexible Alternating Current Transmission Systems (FACTS) device deals with the control of power flow, alternating current of transmission line and immediately respond towards the stability problems of the system. The present paper show that how the FACTS device STATCOM enhance the dynamic response and voltage flicker in distribution network of the power systems. In MATLAB a simplified distribution system is modeled and the find out the desired objectives. D-STATCOM changes from inductive to capacitive operation, the modulation index of the PWM inverter is increased from 0.56 to 0.9 which corresponds to a proportional increase in inverter voltage. Reversing of reactive power is very fast, about one cycle, as observed on D-STATCOM current. Observed on Scope that voltage fluctuation at bus B3 is now reduced to +/- 0.7 %. The D-STATCOM compensates voltage by injecting a reactive current modulated and varying between 0.6 pu capacitive when voltage is low and 0.6 pu inductive when voltage is high.

Authors and Affiliations

Keywords

Related Articles

VERIFICATION OF CARRY LOOK AHEAD ADDER USING CONSTRAINED RANDOMIZED LAYERED TEST BENCH

In processors and in digital circuit designs, adder is an important component. As a result, adder is the main area of research in VLSI system design for improving the performance of a digital system. The performance depe...

PRACTICAL STUDY TO IMPROVEMENT THE PERFORMANCE OF HEAT EXCHANGER USING PASSIVE TECHNIQUES

The aim of this study to improve the performance of heat exchanger by using the medium integral fins on the cross flow heat exchanger practically, so, two the heat exchangers from copper were manufactures with eight pass...

DETERMINATION OF MOISTURE CONTENT IN SOIL BASED ON OVEN DRYING METHOD USING A MICROSTRIP PATCH SENSOR

The proposed design is analyzed of a pentagon shape of microstrip sensor for determination the soil moisture measurement. The proposed design is useful in agricultural field as well as measured the moisture with accuracy...

APPOINTMENT RULER EXCLUSIVE OF MULTIPLE TECHNO DECISION TREES REFLECTION TOWARDS RECITAL FOR EMPLOYABILITY

Invention and new thoughts are discovered mainly from the student’s doubts and questions, for the most part of the word towards “why”. If questioning plays vital roles, in the same way, the sense of answering attitude in...

EXPERIMENTAL MACHINE LEARNING OF FINGER PHOTOPLETHYSMOGRAPHY (PPG) FOR AUTONOMOUS HOSPITAL BED PUSHING FRAMEWORK USING POLYNOMIAL REGRESSION

In community-based healthcare, the nursing workforce requires low-skilled nursing automation in the hospital to accelerate talent development towards high-skilled advance practice nurse for community deployment. As precu...

Download PDF file
  • EP ID EP227726
  • DOI 10.5281/zenodo.569912
  • Views 93
  • Downloads 0

How To Cite

(2017). THE ANALYSIS OF DYNAMIC RESPONSE AND VOLTAGE FLICKER WITH STATCOM ON DISTRIBUTION NETWORK. INTERNATIONAL JOURNAL OF ENGINEERING TECHNOLOGIES AND MANAGEMENT RESEARCH, 4(4), 27-33. https://europub.co.uk/articles/-A-227726