Abstract

Objective To investigate the applicability of Beckman PK7300 for TPPA testing on anti-TP reactive specimens from blood donors. Methods 1) The TPPA test using Beckman PK7300 (abbreviated as instrument method) had been established and the performance was verificated by calculating the total compliance rate, positive compliance rate and negative compliance rate as compared with the manual method. The repeatability of this instrument method was also evaluated. 2) The applicability of the instrument method was evaluated by examing 555 TP-reactive samples for 6 consecutive days, so as to analyze the readable reading rate, agglutination strength distribution and other control methods. Results 1) The total, positive, and negative compliance rates of TPPA detection by both instrumental and manual methods were 100% (kappa value =1). The SPC value of samples, read manually as " + + ", was less than or equal to 3 by Beckman PK7300; the SPC value of samples, read manually as " -", was greater than or equal to 20 by Beckman PK7300. The two methods were well consistent. The instrument method was repeated for 12 times for the same samples, and the accuracy rate was 100% (12 / 12), with good repeatability.2) The results of the TPPA test in 555 anti-TP reactivity specimens showed an overall readable rate of 99.82%(554/555). The SPC values of the negative and unsensitized particles of TPPA were distributed on both sides of the determination value without crossover. The control and monitor thoughout the test were carried out automatically by the instrument. Conclusion The TPPA test conducted by the Beckman PK7300 fully automatic blood group instrument is suitable for the confirmatory experiment of anti-TP reactive specimens in blood center laboratories, which could realize the automation and standardization of TPPA detection.

Authors and Affiliations

Junjie JIA, Zhengmin LIU, Rui WANG, Nan GAO, Rui LIU, Jin GUO

Keywords

Related Articles

Sequential generation of anti-M and anti-Jka leads to two delayed hemolytic transfusion reactions and corresponding strategies

Objective To make transfusion management strategies for patients with history of blood transfusion and/or pregnancy by following up a patient with delayed hemolytic transfusion reactions(DHTR) caused by unexpected antibo...

Effect of applied muscle tension on improving vasovagal reactions among blood donors: a meta-analysis

Objective To systematically evaluate the effect of applied muscle tension (AMT) exercises on reducing vasovagal reactions(VVRs) among blood donors by meta-analysis. Methods Nine related databases including MEDLINE, Web o...

Demographic difference and influencing factors of motivations between whole blood and plasmapheresis donors: a comparative study

Objective To explore the difference of demographics and influencing factors of motivations between whole blood donors and plasmapheresis donors, so as to provide scientific reference for effective recruitment strategy. M...

HBV genotyping and population genetics analysis of voluntary blood donors in five regions of China

Objective To investigate the distribution of Hepatitis B virus(HBV)genotypes and the genetic characteristics of genotype B HBV populations among voluntary blood donors in five regions of China. Methods A total number of...

Study on the correlation between positive psychological capital and communication ability of phlebotomist in Beijing

Objective To analyze the relevant factors affecting the positive psychological capital and communication ability of phlebotomist in blood stations based on the theory of positive psychology and communication behavior, so...

Download PDF file
  • EP ID EP738469
  • DOI 10.13303/j.cjbt.issn.1004-549x.2023.01.018
  • Views 6
  • Downloads 0

How To Cite

Junjie JIA, Zhengmin LIU, Rui WANG, Nan GAO, Rui LIU, Jin GUO (2023). The applicability of Beckman PK7300 fully automatic blood group instrument for TPPA detection. Chinese Journal of Blood Transfusion, 36(1), -. https://europub.co.uk/articles/-A-738469