The Application of Laser and Fibre-Optic Technologies for the Improvement of the Efficiency of Modern Optical Smoke Detectors

Journal Title: Safety & Fire Technology - Year 2018, Vol 49, Issue 49

Abstract

Objective: The aim of the study is to demonstrate the possibility of increasing the sensitivity, resistance to electromagnetic interference and response speed of point smoke detectors on the basis of using laser processing and fibre optics technology. Project and methods: In order to achieve the above goal an optical point smoke detector was designed and produced. The detector uses a laser radiation source and fibre-optic communication line with a radiation receiver. Results: The combined laser-based fire alarm device which includes two smoke detection methods (controlling the intensity of radiation scattered by smoke particles and passed through the smoke without scattering) and carbon monoxide detector are produced. The tests of the fire detector to determine its basic functional parameters and the performance of detecting the test fire sources in accordance with standard SТB 16.03-2009. The minimum threshold quantity of optical smoke density detected in the control channel of the intensity of scattered radiation is 0.05 dB/m. The minimum threshold quantity of optical smoke density detected in the control channel of the intensity of radiation passing through the smoke without scattering is about 0.9 dB/m for controlled optical length 25 mm. The minimum concentration of carbon monoxide detection by the CO gas detector is 40 ppm. The testing results of combined laser-based fire alarm device on the detection efficiency of the standardised fire source bear record to its hypersensitivity for different types of smoke and a higher speed of detection of fires in comparison with single-channel point smoke detector. The tests of the combined laser fire detector to determine the efficiency of the fire detection model point to its increased sensitivity to different types of smoke and fire detection speed in comparison with a conventional single-channel point smoke detector. Using fibre optics for recording radiation getting through smoke without dissipation showed us the possibility of developing a point smoke detector on the linear principle of smoke detection with signal processing at a distance from the controlled zone in a well-screened box, for instance, inside a fire alarm control panel. Obviously, the signaling device will be highly resistant to electromagnetic interference due to the reliable screening of the sensitive elements of the electronic signal processing system and the lack of wiring connected to the fire alarm control panel. Conclusions: The advanced functional characteristics of the fire alarm device are provided thanks to the application of a laser source with a high intensity and a low divergence of radiation. The unique properties of laser radiation in the sensor’s structure made it possible to apply a number of design and technical solutions which provided a substantial increase in the sensitivity and fire detection rate of the sensor compared to the currently used traditional LED smoke detectors.

Authors and Affiliations

Y. S. Ivanov

Keywords

Related Articles

Doskonalenie działań zorganizowanych

Cel: Uzasadnienie potrzeby doskonalenia działań zorganizowanych w kontekście nieuchronności zmian oraz wskazanie sposobów pomiaru efektywności działania organizacji i wybranych technik usprawniających jej funkcjonowani...

O wojnie i pokoju – dylematy polemologiczne

ABSTRAKT Cel: Celem artykułu jest przedstawienie zjawiska wojny i pokoju w kontekście polemologicznym. W artykule zaprezentowano wybrane pojęcia, definicje i teorie wojny oraz podjęto próbę identyfikacji wiedzy polemolog...

A Mathematical Model of the Change of Hydrogen Concentration. Sample Computations for a Real-Life Situation in a Ventilated Room

Objectives: The aim of this article is to analyse the change of concentration of hydrogen in the atmosphere of large closed spaces with a constant but small emission of hydrogen. The analysis has been conducted for a roo...

Research Projects Dealing with Civil Protection – Selected Issues

Introduction: The article provides an analysis and diagnosis of selected research projects dealing with civil protection, taking into account their functional, cognizant and organizational aspects. The study focused on t...

Influence of Wooden-Based Dusts on Smoke Fire Detectors

Aim: There is a need of fire detection solutions which are sensitive to deceptive signals. They can lead to false fire alarms. One of such signals is the activation of detectors in case of wooden dusts accumulated in the...

Download PDF file
  • EP ID EP359758
  • DOI 10.12845/bitp.49.1.2018.8
  • Views 75
  • Downloads 0

How To Cite

Y. S. Ivanov (2018). The Application of Laser and Fibre-Optic Technologies for the Improvement of the Efficiency of Modern Optical Smoke Detectors. Safety & Fire Technology, 49(49), 86-92. https://europub.co.uk/articles/-A-359758