THE APTUS™ HELI-FX™ ENDOANCHOR™ SYSTEM – THE INNOVATIVE ENDOVASCULAR REPAIR METHOD FOR THE PATIENT WITH POSTEVAR TYPE IA ENDOLEAK

Journal Title: Acta Neuropsychologica - Year 2017, Vol 15, Issue 2

Abstract

[b]Background:[/b] The aim of our study was to present an innovative endovascular technique – the Aptus™ Heli-FX™ EndoAnchor™ system com bined with the Endurant Stent Graft cuff used as a method of choice for the patient in a very poor general condition with symptomatic abdominal aneurysm and a post-EVAR type IA endoleak.[b]Case study: [/b]An 85-year-old male patient, was operated on in March 2016 with endovascular aneurysm repair (EVAR) of a 9.3 cm in diameter ruptured abdominal aneurysm (RAA), accompanied by disturbance to the coagulation profile (prolonged INR of 3.3 because of anticoagulant treatment with Rivaroxaban due to atrial fibrillation). 9 months later, he developed a severe abdominal pain and was urgently referred to the Vascular Surgery Department, at the John Paul II Hospital, Kraków. The Angio-CT xamination revealed the type IA and II endoleaks and a recurrence of the rupture symptoms. He was successfully operated on using an innovative endovascular repair system, the Aptus™ Heli-FX™ ndoAnchor™ system with a combination of other endovascular procedures, such as Endurant Stent Graft cuff implantation. [b]Conclusions:[/b]The innovative endovascular repair system, Aptus™ Heli-FX™ EndoAnchor™ together with the Endurant Stent Graft cuff was successfully used in the treatment of the patient. This technique prevented him from developing serious complications or even death and gave him a much better quality of life in comparison with open surgery repair.

Authors and Affiliations

Tomasz Muszyński, Karina Polak, Julia Krzywoń, Katarzyna Zbierska-Rubinkiewicz, Mariusz Trystuła

Keywords

Related Articles

The effects of proprioception on memory: a study of proprioceptive errors and results from the Rey-Osterrieth Complex Figure in a healthy population

The aim of the current study was to test whether or not proprioceptive errors (biases) are associated with visual memory performance, and to distinguish which movement types are more important in this relationship.The st...

LEVEL OF EMOTIONAL AND SOCIAL COMPETENCE IN ADULT PERSONS WITH SYMPTOMS OF HYPERACTIVITY DISORDER

The present study concerns adults with symptoms of hyperkinetic syndrome. According to the literature, the main problems in comparison to persons without ADHD symptoms include difficulties in the verbal expression of emo...

PERCEPTUAL MICROGENESIS – WHAT ARE ITS REAL-TIME CHARACTERISTICS?

According to the microgenetic stance, each following instant of perception gradually grows out from the each preceding one and is essentially a continual part of it. It is difficult to exclusively differentiate past, pre...

Gogi aphasia: The early description of semantic dementia in Japan

Thirty years preceding the first detailed reports of semantic dementia (SD) in western countries, Imura described a unique aphasic syndrome exhibited in Japanese patients, which he called gogi (literally, “word-meaning”)...

THE IMAGE OF A CHILD WITH FACIAL DYSMORPHISM IN A MOTHER’S PERCEPTION

Background: Facial dysmorphisms are very often an integral component of numerous genetic syndromes. There is an especially clear link between facial dysmorphism and deeper intellectual disability. The coupling of the for...

Download PDF file
  • EP ID EP205879
  • DOI 10.5604/01.3001.0010.2408
  • Views 81
  • Downloads 0

How To Cite

Tomasz Muszyński, Karina Polak, Julia Krzywoń, Katarzyna Zbierska-Rubinkiewicz, Mariusz Trystuła (2017). THE APTUS™ HELI-FX™ ENDOANCHOR™ SYSTEM – THE INNOVATIVE ENDOVASCULAR REPAIR METHOD FOR THE PATIENT WITH POSTEVAR TYPE IA ENDOLEAK. Acta Neuropsychologica, 15(2), 181-187. https://europub.co.uk/articles/-A-205879