The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities

Journal Title: Roczniki Państwowego Zakładu Higieny - Year 2017, Vol 68, Issue 1

Abstract

Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.

Authors and Affiliations

M. Bekas, E. Waśniewska, A. Wardziński, K. Wieprzowski

Keywords

Related Articles

Consumption of black and green teas as a dietary source of polyphenols in Polish inhabitants of the Mazovian region

Background. Tea is a very popular drink throughout many parts of the world, that includes Poland. The tea infusion (cup of tea) itself contains phenolic compounds with anti-oxidant properties that constitute 30% of the d...

Holistic measurement of well-being: psychometric properties of the physical, mental and social well-being scale (PMSW-21) for adults

Background. A holistic approach to health requires the development of tools that would allow to measure the inner world of individuals within its physical, mental and social dimensions. Objectives. To create the Physica...

Furan in roasted, ground and brewed coffee

Coffee is the most popular hot beverage in the world. The annual coffee production in 2010, 2014 and 2016 was 8.1, 9.0 and 9.3 million tons respectively. There are more than 100 coffee species, but only two of them: Arab...

Evaluating adult dietary intakes of nitrate and nitrite in Polish households during 2006-2012

Introduction. Nitrates and nitrites commonly occur throughout nature as well as in foodstuffs. Their excess consumption can however pose health risks, for example, arising from methaemoglobinaemia or from the formation o...

Health risk as a consequence of exposure to trihalomethanes in swimming pool water

The article presents the formation and toxicity of trihalomethanes (THMs), substances belonging to Disinfection By-Products (DBP), formed as a result of pool water chlorination. Concentration of THMs in pool water has be...

Download PDF file
  • EP ID EP318965
  • DOI -
  • Views 47
  • Downloads 0

How To Cite

M. Bekas, E. Waśniewska, A. Wardziński, K. Wieprzowski (2017). The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities. Roczniki Państwowego Zakładu Higieny, 68(1), 99-103. https://europub.co.uk/articles/-A-318965