The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities
Journal Title: Roczniki Państwowego Zakładu Higieny - Year 2017, Vol 68, Issue 1
Abstract
Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.
Authors and Affiliations
M. Bekas, E. Waśniewska, A. Wardziński, K. Wieprzowski
Mineral supplements’ effect on total nutrient intake in Warsaw adult population; cross-sectional assessment
Background. Mineral supplementation is important whenever any dietary deficiencies of these nutrients occur. However, an excessive consumption of such products can lead to the negative health consequences. Objectives. T...
Assessment of physical activity, energy expenditure and energy intakes of young men practicing aerobic sports
Background. Adequate nutrition and energy intake play key rule during the training period and recovery time. The assessment of athlete’s energetic needs should be calculated individually, based on personal energy expendi...
Comparing of nutrients content and calorific value in the diets of Poles and Greeks living in Athens
Background. Diet is generally defined as a set of behaviors, on the choice of certain foods, their consumption, and it is conditioned by various factors. Each model is shaped feeding in a given place and time by repeated...
Evaluation of selected dietary behaviours of students according to gender and nutritional knowledge
Introduction. Nutrition is a factor influencing physical and mental fitness. In this study we examine the lifestyle of university students and its impact on nutritional errors. Objective. To evaluate the dietary behavi...
Evaluation of communication and acceptance of the patients by medical personnel
Background. The low level of patient satisfaction recorded in many studies and, at the same time, the level of frustration and burnout, disclosed by medics in the perception of the patient as a ‘problem’, incline to look...