The Comparison of Fluid Dynamics Parameters in an Andersen Cascade Impactor Equipped With and Without a Preseparator

Journal Title: AAPS PharmSciTech - Year 2014, Vol 15, Issue 3

Abstract

The fluid dynamic data in Andersen cascade impactor (ACI) are still lacking. Airflows and those affected parameters can be predicted in a preseparator and Andersen cascade impactor (ACI) by computational modeling. This study developed a validated computational fluid dynamic (CFD) model of an ACI and investigated the effects of the preseparator on the CFD parameters. Validation of the computational nozzle velocity for each of the stage 0 to stage 5 of the ACI stages was found to be within a 3.56% error. The flow field indicated that the preseparator accelerated the airflow velocity at the induction tube from 1.13 to 3.71 ± 0.09 m/s and 2.40 to 8.68 ± 0.16 m/s (at 28.3 and 60 L/min of flow rate, respectively). The preseparator produced a nozzle's wall shear stress ranged from 0.08 to 0.34 Pa on a collection plate, while the ex-preseparator spread wall shear from the plate's center was in a range of 0.11 to 0.37 Pa (at 28.3 L/min of flow rate). Moreover, the nozzle velocities increased along the distance from the middle of the collection plate to the periphery. The CFD explained the airflow of the preseparator equipped model by accelerating the airflow along the inlet port to maximize the trapping of desirable particles and the generation of a smooth wall shear stress at the collection plate to reduce the particle re-entrainment. While, the ex-preseparator generated an airflow that resulted in a higher wall shear stress occurring on the lower stages.

Authors and Affiliations

Janwit Dechraksa, Tan Suwandecha, Kittinan Maliwan, Teerapol Srichana

Keywords

Related Articles

Formulation and Optimization of Nonionic Surfactants Emulsified Nimesulide-Loaded PLGA-Based Nanoparticles by Design of Experiments

This investigation aimed to develop nimesulide (NMS)-loaded poly(lactic-co-glycolic acid) (PLGA)-based nanoparticulate formulations as a biodegradable polymeric drug carrier to treat rheumatoid arthritis. Polymeric nanop...

Recent Trends in Product Development and Regulatory Issues on Impurities in Active Pharmaceutical Ingredient (API) and Drug Products. Part 2: Safety Considerations of Impurities in Pharmaceutical Products and Surveying the Impurity Landscape

There are inconsistent identification and qualification thresholds for impurities in drug substances and drug products, particularly for degradation impurities that may be common to both a drug substance and a correspond...

Compression-Coated Tablet for Colon Targeting: Impact of Coating and Core Materials on Drug Release

This work was envisaged to develop compression-coated tablets using a blend of Ca+2 ion cross-linked carboxymethyl xanthan gum (CMXG) and sodium alginate (SAL) for delayed release of immediate pulse release tablets of pr...

A Systematic Approach to Design and Prepare Solid Dispersions of Poorly Water-Soluble Drug

The objective of the present study was to define a systematic approach to design and prepare solid dispersions of poorly water-soluble drug. The systematic approach can be defined in four phases. In the first phase, glas...

Influence of Processing Parameters and Formulation Factors on the Bioadhesive, Temperature Stability and Drug Release Properties of Hot-Melt Extruded Films Containing Miconazole

This study investigated the processing parameters and formulation factors on the bioadhesive properties, temperature stability properties, and drug release properties of miconazole in PolyOx® and Klucel®...

Download PDF file
  • EP ID EP682406
  • DOI  10.1208/s12249-014-0102-2
  • Views 107
  • Downloads 0

How To Cite

Janwit Dechraksa, Tan Suwandecha, Kittinan Maliwan, Teerapol Srichana (2014). The Comparison of Fluid Dynamics Parameters in an Andersen Cascade Impactor Equipped With and Without a Preseparator. AAPS PharmSciTech, 15(3), -. https://europub.co.uk/articles/-A-682406