The Dynamics of Dry Chemical Powder Particles Towards the Fire Source During Their Pulse Feeding into the Combustion Zone
Journal Title: Safety & Fire Technology - Year 2018, Vol 49, Issue 49
Abstract
Objective: Currently, the pulse-type dry chemical extinguishing system (DCES) is extensively used for extinguishing fires. These units generally consist of a control junction and powder extinguishing modules (PEM) filled with fire extinguishing powder and gas pumped into the module under the high pressure. Giving extinguishing powder from the PEM in the fire source is carried out when exposed to the heated air of the thermal column generating lift. The magnitude of this force depends on the power of fire and intensity of air change in the room. The efficiency of fire extinguishing with the DCES in these conditions will be determined not only by the powder extinguishing ability but also its dynamic characteristics when approaching the fire. In the design of pulse-type fire extinguishing systems using PEMs it should be considered that during testing PEMs the dynamics of the gas powder mixture released from the module is impacted by the air resistance and the lift of the heated gases from the thermal column from the fire source. Aim: The aim of this work is to determine the ratio of the unit weight of dry chemical extinguishing powder depending on the distance from the nozzle of the DCES for the defined pneumatic and loading characteristics of the system, disperse parameters of dry chemical powder and the fire power. Project and methods: To reach the aim of the study, a mathematical model approach was applied for the flow process the extinguishing substance from the DCES and its movement in open-air space towards the fire. Results: A mathematical model was developed to calculate the movement dynamics of the gas-powder mixture in an open-air space towards the fire source under specific performance parameters of the DCES and the power of the fire. A correlation for estimating the extinguishing powder particle velocity at different distances from the DCES nozzle during their movement towards the fire of a given power was obtained. An experimental study of the dynamics of the front of the powder mixture ejected from the pulse-type PEM was performed. The analysis of the results showed their satisfactory level of compliance with numerical calculations. Conclusions: The obtained results can be used for analyses of pulse-type PEMs with a goal of assessing the spatial and energy parameters of fires which can be extinguished using this method. The results can be used during the design of such installations in order to specify the pneumatic and load parameters of the module associated with the given technical characteristics of the extinguishing agent, the assumed power level of the fire source and the height of the PEM.
Authors and Affiliations
A. I. Kitsak, Ph. D.
An Analysis of the Selection of Riser Diameters in Firefighting Water-Supply Systems in High-Rise Buildings
Aim: This article is aimed at analysing the validity of the selection of diameters for risers in the water-supply systems of high-rise buildings, on the basis of the regulations in force. Central focus was placed on the...
Sposób doprowadzenia powietrza kompensacyjnego a wzdłużna wentylacja pożarowa stacji metra
Cel: Przedstawienie wyników badań własnych autorów w obszarze systemów wentylacji podziemnych obiektów kolejowych na przykładzie sieci metra. Badania obejmowały przede wszystkim powiązanie wpływu sposobu doprowadzenia po...
Динамика частиц огнетушащего порошка на пути к очагу пожара при импульсном способе подачи его в зону горения
Цель: В настоящее время для тушения пожаров широко используются модульные установки порошкового пожаротушения (МУПП) им- пульсного типа. Данные установки состоят, как правило, из узлов управления и модулей порошкового по...
Doskonalenie działań zorganizowanych
Cel: Uzasadnienie potrzeby doskonalenia działań zorganizowanych w kontekście nieuchronności zmian oraz wskazanie sposobów pomiaru efektywności działania organizacji i wybranych technik usprawniających jej funkcjonowani...
Approaches to Extinguish Gas Blowout Fires: World Experience and Potential for Development
Aim: Fires caused by a gas blowout are complex man made emergencies. Attempts to extinguish such fires attracts considerable effort and resources. Such incidents culminate in significant financi...