The Effect of Cavity Design on Fracture Resistance and Failure Pattern in Monolithic Zirconia Partial Coverage Restorations - An In vitro Study
Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 5
Abstract
Introduction: Cavity preparations of posterior teeth have been frequently associated with decreased fracture strength of the teeth. Choosing the correct indirect restoration and the cavity design when restoring the posterior teeth i.e., premolars was difficult as it involves aesthetic, biomechanical and anatomical considerations. Aim: To evaluate the fracture resistance and failure pattern of three different cavity designs restored with monolithic zirconia. Materials and Methods: Human maxillary premolars atraumatically extracted for orthodontic reasons were chosen. A total of 40 teeth were selected and divided into four groups (n=10). Group I-Sound teeth (control with no preparation). Group II-MOD Inlay, Group III-Partial Onlay, Group IV-Complete Onlay. Restorations were fabricated with monolithic partially sintered zirconia CAD (SAGEMAX- NexxZr). All the 30 samples were cemented using Multilink Automix (Ivoclar) and subjected to fracture resistance testing using Universal Testing Machine (UTM) (Instron) with a steel ball of 3.5 mm diameter at crosshead speed of 0.5 mm/minute. Stereomicroscope was used to evaluate the modes of failure of the fractured specimen. Fracture resistance was tested using parametric one way ANOVA test, unpaired t-test and Tukey test. Fracture patterns were assessed using non-parametric Chi-square test. Results: Group IV (Complete Onlay) presented highest fracture resistance and showed statistical significant difference. Group II (MOD Inlay) and Group III (Partial Onlay) showed significantly lower values than the Group I (Sound teeth). However, Groups I, II and III presented no significant difference from each other. Coming to the modes of failure, Group II (MOD Inlay) and Group III (Partial Onlay) presented mixed type of failures; Group IV (Complete Onlay) demonstrated 70% Type I failures. Conclusion: Of the three cavity designs evaluated, Complete Onlay had shown a significant increase in the fracture resistance than the Sound teeth.
Authors and Affiliations
Madhavareddy Sri Harsha, Mynampati Praffulla, Mandava Ramesh Babu, Gudugunta Leneena, Tejavath Sai Krishna, G Divya
Clarification of Quantitative Intraoral Circumstances with the Community Periodontal Index of Treatment Needs Data using Covariance Structure Analysis
ABSTRACT Introduction: Although the severity of periodontal disease is evaluated by various indices, the susceptibility is different among tooth types in the same dentition. Community Periodontal Index of Treatment Needs...
Colloid Cyst – A Small Third Ventricle Cyst with Unusual Psammomatous Calcifications
We report a case of a colloid cyst in the foramen of Monro, with an unusual finding of psammomatous calcifications. Colloid cysts of the third ventricle with calcifications in the wall are very rare. Colloid cysts are be...
Management of Double Lip
Images in Medicine
Bacteriological Profile of Wounds Due to Occupational Injuries among Fisherman Community of Puducherry, India
ABSTRACT Introduction: Fishermen are more prone to wound infections because of their working environment. Secondary bacterial infection due to poor sanitary conditions among such a community can result in further contam...
Apical Extrusion of Debris in Mesiobuccal Root of Maxillary Molars with Five Rotary File Systems
ABSTRACT Introduction: Flare-ups in endodontics are multifactorial and may cause severe discomfort to the patient. Apical extrusion while preparing root canal space in any form such as debris, bacteria or irrigants has b...