The Effect of Cooling Vest on Heat Strain Indexes and Reaction Time While Wearing Chemical-Microbial-Radioactive Protective Clothing in Hot and Dry Laboratory Conditions

Journal Title: UNKNOWN - Year 2016, Vol 8, Issue 4

Abstract

Background: Heat is a harmful factor in workplaces that causes physiologic and cognitive changes in workers. Objectives: The purpose of this study was to investigate the effect of cooling vest on heat strain and reaction time while wearing chemical-biological-nuclear protective clothes. Methods: Twelve male students with mean age of 25 ± 2 and body mass index (BMI) of 23 ± 1.5 were recruited in the experiment. Each student ran on a treadmill with a speed of 2.4 km/hour in the climate chamber at 35°C and 30% relative humidity. physiological strain index score, oral temperature, heart rate, reaction time and number of errors were measured at the end of the two levels and analyzed by the SPSS software. Results: Wilcoxon test showed that the differences of physiological strain index score (P = 0.02), oral temperature (P = 0.02), reaction time (P = 0.02), heart Rate (P = 0.02) and errors (P = 0.03) with and without the cooling vest were significant. The mean physiological strain index score without cooling vest was 4.038 ± 0.882 and with the cooling vest was 1.42 ± 0.435. The mean reaction time without and with the cooling vest was 0.769 ± 0.0972 and 0.539 ± 0.977, respectively. Conclusions: The results of the study showed that the cooling vest reduces the physiological strain, reaction time and errors rate of workers.

Authors and Affiliations

Habibollah Dehghan, Firouz Valipour, Hossein Khalili Gorji, Behzad Mahaki

Keywords

Related Articles

Association Between HLA-A*02 Genotype and Multiple Sclerosis in Khuzestan Province, Iran

Background: Multiple sclerosis (MS) is a chronic, inflammatory, demyelinating, and neurodegenerative autoimmune disease of the central nervous system (CNS). In the disease, the immune system attacks myelin sheath around...

An Investigation of Respiratory Symptoms and Spirometry Parameters of Welders in a Steel Industry

Background: Fumes released form welding activities are capable of initiating several acute and chronic respiratory effects. Objectives: The aim of the present study was to evaluate respiratory symptoms and spirometry pa...

Survey of Knowledge and Attitude Toward Emergency Contraceptive Method Among Married Women in Reproductive Age Group

Background: Unwanted pregnancy (UP) is a worldwide problem. UP mainly results from the improper or lack of use of effective contraceptive methods. Hormonal emergency contraceptive (EC) is a method of family planning that...

Safety Signs Perception and Adoption with the ISO and ANSI Standards

Background: One way of controlling hazards in the work environment is a use of safety signs. Safety signs are among the safe information group; hence, if these signs are not understood properly it could cause an injury o...

Prevalence and Associated Factors of High Blood Pressure in Urban Setting of Kandahar City in Afghanistan in 2015

Background: Hypertension is an important public health problem, which is prevalent and asymptomatic, with modifiable and preventable risk factors. Afghanistan is suffering from double burden of diseases including communi...

Download PDF file
  • EP ID EP291429
  • DOI 10.17795/jjhs-33960
  • Views 58
  • Downloads 0

How To Cite

Habibollah Dehghan, Firouz Valipour, Hossein Khalili Gorji, Behzad Mahaki (2016). The Effect of Cooling Vest on Heat Strain Indexes and Reaction Time While Wearing Chemical-Microbial-Radioactive Protective Clothing in Hot and Dry Laboratory Conditions. UNKNOWN, 8(4), 1-5. https://europub.co.uk/articles/-A-291429