The Effect of Different Techniques of Microwave Disinfectionon Elastomeric Impression Materials (Laboratory and Microbiological Study)

Journal Title: Journal of Medical Science And clinical Research - Year 2016, Vol 4, Issue 10

Abstract

Dental impressions are often contaminated by exposure to saliva and blood. Microwave irradiation and immersion in solutions have been recommended for denture disinfection. However, the effect on impression materials has not been studied enough. Accordingly, the question is, is it possible to apply "Microwave disinfection" to impression materials vinyl siloxanether, polyvinyl siloxane and polyether? And if yes is it better to use with or without hydrogen peroxide (H2O2)? The Aim of this study is to evaluate and compare the effect of different techniques of microwave disinfection (microwave for 1 minute, 3 minutes and microwave with H2O2 for 1 minute and 3 minutes) on elastomeric impression materials (laboratory and microbiological study). Martials and methods: Specimens were made with vinyl siloxanether (Group I), polyvinyl siloxane (Group II) and polyether (Group III). Experimental groups were divided into Subgroup I :No disinfection measures (control group) , Subgroup II: The disinfection of samples were carried using microwave 630 w immersed in saline for 1 minute, Subgroup III: The disinfection of samples were carried using microwave 630 w immersed in saline for 3 minutes, Subgroup IV: The disinfection of samples were carried using microwave 630 w immersed in hydrogen peroxide for 1 minute, Subgroup V:The disinfection of samples were carried using microwave 630 w immersed in hydrogen peroxide for 3 minutes. The disinfection effect on bacteria and physical properties of impressions were evaluated. Result; Different techniques were significantly different (P< .05) when compared with the control in reducing the number of colony forming units (CFU) per unit volume (mL) for both streptococcus mutans and candida albicans. The most significant reduction in the CFU/mL was noted when the disinfection of samples was carried using microwave 630 w with hydrogen peroxide for 3minutes. No statistically significant difference was noted between the control and treatment groups in terms of all the physical properties tested (P>.05). Conclusion; Microwave disinfection decreased the CFU/ml of microorganisms in dental impressions, but it is more effective when samples immersed in hydrogen peroxide. Microwave disinfection with or without hydrogen peroxide had no effect on physical properties of polyvinyl siloxanether and polyvinyl siloxane but cause dimensional changes for polyether.

Authors and Affiliations

Ahmed Abd El-Hamid

Keywords

Related Articles

The Region of Interest in Determining the Proper Value of Full-Width at Half Maximum during Magnetic Resonance Spectroscopy

Background: MRS is an advanced examination of MRI producing a spectra that describe metabolite information of tissues. ROI setting becomes very important in generating the spectral diagnostic value called Full-Width at H...

Takayasu Arteritis and PRES Syndrome - A Rare Case Series

PRES is a very rare manifestation of Takayasu’s arteritis. It can present with headache, seizures, altered sensorium with visual disturbances. Two young teenager patients presented in ward with complaints of severe heada...

Influence of Yoga on Audiovisual Reaction Time of Medical Students

Aim: The present study is to assess the alteration in auditory and visual reaction time, which is an index of central nervous system processing, among medical students. Materials and Methods: Eighty healthy volunteers we...

Functional & Radiological Outcome of the Volar Locking Plate Fixation for Fracture of the Distal End Radius

Introduction: Fractures of the lower end of the radius are most common fractures of the upper extremity, encountered in practice and constitute 17 % of all fractures and 75% of all forearm fractures. Distal radius fractu...

Assessment of the Effects of Fresh Palm Oil, Natron (Kanwa) and NatronTreated Palm Oil on Some Hematological Parameters in Wistar Rats

The effect of fresh palm oil, natron (kanwa) and natron-treated palm oil on some hematological parameters were assessed in wistar rats. Twenty- four wistar rats of different sexes weighing between 123-217g were divided i...

Download PDF file
  • EP ID EP214586
  • DOI -
  • Views 26
  • Downloads 0

How To Cite

Ahmed Abd El-Hamid (2016). The Effect of Different Techniques of Microwave Disinfectionon Elastomeric Impression Materials (Laboratory and Microbiological Study). Journal of Medical Science And clinical Research, 4(10), 13251-13255. https://europub.co.uk/articles/-A-214586