The Efficacy of the Volume of Hyperbaric Bupivacaine Used and Its Influence on Spinal Anaesthesia Induced Hypotension during Caesarean Section

Journal Title: Asian Journal of Medicine and Health - Year 2016, Vol 1, Issue 3

Abstract

Aims: To audit the spinal anaesthesia practice among physician anaesthetists and to determine the lowest effective volume of hyperbaric bupivacaine that could minimise the incidence of spinal anaesthesia induced hypotension during caesarean section. Study Design: It was a prospective observational study of patients undergoing caesarean section. Patient recruitment was by convenient sampling. Place and Duration of Study: The study was carried out at the Obstetric theatre of the University of Calabar Teaching Hospital, Calabar, Nigeria between March and June 2015. Methodology: One hundred and thirty one (131) patients who met the inclusion criteria were recruited for the study. Patients with antepartum haemorrhage, pregnancy-induced hypertension or patients on any antihypertensive agents and those with contraindications to spinal anaesthesia were excluded. The spinal anaesthesia was instituted at L3 L4 interspace in the sitting position. The maximum height of sensory block and the number of patients that were hypotensive (systolic blood pressure less than 90 mmHg) in relation to the volume of hyperbaric bupivacaine used were noted. Simple descriptive and inferential statistics was used to determine the association between the volumes of hyperbaric bupivacaine used, the height of block and incidence of hypotension. Results: The volumes of 0.5% hyperbaric bupivacaine used ranged from 1.5– 2.7 millilitres (mls). Sixty-eight (51.9%) patients received treatment for hypotension. The incidence of hypotension was related to volume of bupivacaine used and height of sensory block. The incidence of hypotension was more in patient that had 2 mls (62.9%). Less than 2mls was associated with lower incidence of hypotension (32.5%) but with a high risk of intraoperative analgesic requirement (22.5%). A block height below T6 was a risk factor for supplementary intraoperative analgesic requirement and above T6 risk factor for hypotension. The maximum height of sensory block did not have any significant relationship with the volume of the hyperbaric bupivacaine used, (P = 0.1). Conclusion: Spinal anaesthesia-induced hypotension is a complication that may not be eliminated. The incidence during caesarean section in this study was influenced more by height of block than volume of the drug used. The used of 1.5 mls (7.5 mg) of 0.5% hyperbaric bupivacaine and a block height of T6 could provide adequate anaesthesia for caesarean section and reduce the incidence of hypotension.

Authors and Affiliations

I. U. Ilori

Keywords

Related Articles

Ameliorative Potentials of Yoyo Bitters and Aqueous Leaf Extract of Moringa oleifera in Arsenite Induced Inflammatory Dysfunctions in Male Wistar Rats

Background: The use of alternative therapy to combat heavy metal intoxications has emerged recently, due to scientific evidences indicating superior efficacy in the use of botanicals that possess high antioxidative capab...

Benign Breast Diseases in Makurdi, North Central Nigeria: A Retrospective Review of One Hundred and Thirty Five (135) Cases

Benign Breast Disease (BBDs) encompasses a diverse group of lesions that may present with a wide range of symptoms or may be detected as incidental microscopic findings. We presented a retrospective review of 249 cases o...

Real Time Polymerase Chain Reaction versus Enzyme Linked Immunosorbent Assay in the Diagnosis of Cytomegalovirus Infection in Pregnant Women

Background: Cytomegalovirus infection is endemic worldwide. Most frequently used methods for antibodies detection in developing world are enzyme linked immunosorbent assay. The polymerase chain reaction induces productio...

Effects of Extracts of Anchomanes difformis on Female Sex Hormones: Preliminary Results

This study assessed the effects of extracts of Anchomanes difformis on female sex hormones in albino wistar rats. Forty female albino wistar rats weighing between 150-200 g divided into five groups of eight rats each wer...

Comparative Analysis of the Duration of Urethral Catheterization for Caesarean Delivery

Aims: To compare the effect of spontaneous voiding of urine to the different durations of the urethral catheter following elective caesarean section. Study Design: Cross-sectional. Place and Duration of Study: Departme...

Download PDF file
  • EP ID EP350556
  • DOI 10.9734/AJMAH/2016/29234
  • Views 61
  • Downloads 0

How To Cite

I. U. Ilori (2016). The Efficacy of the Volume of Hyperbaric Bupivacaine Used and Its Influence on Spinal Anaesthesia Induced Hypotension during Caesarean Section. Asian Journal of Medicine and Health, 1(3), 1-8. https://europub.co.uk/articles/-A-350556