THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE

Abstract

Introduction. Development of cables for structured cabling systems based on twisted pairs for shipbuilding is carried out in two main directions: increasing the fire safety of cables and increasing the long-term permissible operating temperature by using new, more heat-resistant, electrical insulating materials. Purpose. Substantiation of the possibility of unshielded cables on the basis of unshielded twisted pairs with thermoplastic polyethylene insulation in PVC protective jacket in conditions of high humidity and high operating temperatures on the basis of the results of accelerated aging. Methodology. The cycle of aging under conditions of increased humidity is performed for 336 hours. Then the sample was under natural drying conditions for 1440 hours. Thermal aging in a thermostat at 90 °C was carried out in two stages: first – for 206 hours, the second – for 260 hours. In the initial state and after accelerated aging, measurements of the capacitance and tangent of the dielectric loss angle of all the insulating gaps at frequencies of 100 Hz, 1 and 10 kHz were performed. Results. According to the results of accelerated aging under conditions of high humidity and temperature, it is established that the design of an unshielded cable based on unshielded twisted pairs with thermoplastic polyethylene insulation in a protective coating based on PVC-plastic is resistant to external influencing factors. Practical value. The prolonged holding at temperature of 90 °C is equivalent to operation at temperature of 40 °C for 6.8 years. At higher operating temperatures, the lifetime of the cable is significantly reduced.

Authors and Affiliations

G. V. Bezprozvannych, I. A. Mirchuk

Keywords

Related Articles

THE TIME ELEMENT IN THE STRATEGY OF ELECTRIC GRIDS IMPROVEMENT

The article considers optimization questions for parameter series of wire cross-sections as basis of overhead line unification in the strategy of electric grid improvement to allow taking into account design load variati...

THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE

Introduction. Development of cables for structured cabling systems based on twisted pairs for shipbuilding is carried out in two main directions: increasing the fire safety of cables and increasing the long-term permissi...

TECHNICAL AND ECONOMIC ASPECTS OF ELECTRIC MACHINE INDUSTRY DEVELOPMENT WITH ACCOUNT OF ELECTRIC POWER DEVELOPMENT DIRECTIONS

A critical assessment of the existing views on the world energy development prospects is an integral part of independent policy elaboration in this field for any state. Consideration of prospective power industry develop...

REACTIVE CURRENT OF AN INDUCTION ELECTRIC DRIVES WITH THYRISTOR VOLTAGE REGULATOR

A model for a separation of reactive constituent from current of idling of an induction motor at its feed from a thyristor voltage regulator in the dependences on the control angle of thyristors is developed. As a result...

ELECTROMAGNETIC FIELD OF A CABLE WITH A TWO-LAYER SHIELD

The paper presents electromagnetic field calculations for a coaxial cable with a double-layer shield. To describe the conductivity and permeability, discontinuous functions are applied, which makes it possible to solve t...

Download PDF file
  • EP ID EP293522
  • DOI 10.20998/2074-272X.2017.5.08
  • Views 87
  • Downloads 0

How To Cite

G. V. Bezprozvannych, I. A. Mirchuk (2017). THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE. Електротехніка і Електромеханіка, 0(5), 51-54. https://europub.co.uk/articles/-A-293522