Abstract

Global warming, rise in life standards, and so on increase the demand for cooling and air-conditioning systems every passing day. Various methods are used to enhance the performance of these systems. One of these methods is the use of evaporative condenser in cooling systems. This study makes an experimental analysis of the effects of using evaporative condenser in cooling systems on system performance. The condenser unit of the experimental system was cooled through adiabatic humidification method. Adiabatic humidification process was carried out by using nozzles with diameters of 0.2, 0.3, and 0.4 mm. The system was thermodynamically analyzed for the use of air-cooled condenser and different nozzle diameters, thereby comparing the cooling performances of the system. The obtained data shows that the use of evaporative condenser led to a decrease of 8.48% in the work of compressor, an increase of 32.92% in the COP value of the cooling system, and an increase of 18.43% in the COP value of the entire system.

Authors and Affiliations

Ali Etem GÜREL, Abdulaziz YILDIZ, Emrah DENİZ

Keywords

Related Articles

Investigation of the Effect of Chip Breaker Form on Surface Roughness and Cutting Forces in AISI 1040 Steel Milling

In this study, the effects of chip breaker forms (E-PL, M-PL, M-PM, M-MM) on the surface roughness and cutting forces were investigated in milling of AISI 1040 steel at CNC vertical machining center. Experimental studies...

Wall Solar System Working Principle and Applicability in Turkey

Solar wall is an auxiliary system for heating buildings. It is used to preheat the air passing through it so as to reduce the load of heating system of the building. It makes the heating system economically more efficien...

Comparison of Active Soil Thrusts Acting on the Retaining Walls According to Eurocode-8 and Turkish Earthquake Code

Earthquake codes have been periodically revised and updated depending on the technical literature improvements. This revises and update in earthquake codes has been generally performed on the design methods. In this pape...

Design and construction of low cost sensor and GPS based autonomous unmanned ground vehicle

In recent years, unmanned vehicles have been quite popular for the researchers and those vehicles are still being developed by the researchers and engineers. Unmanned vehicle must do all operations without operator and m...

Traditional City Pattern and Houses of Çanakkale-Bozcaada

Looking closely to Bozcaada architectural characteristics, it is possible to see Turkish and Rum influence. For instance, the houses in Alaybey neighborhood have the architectural characteristics of the former, while the...

Download PDF file
  • EP ID EP479240
  • DOI -
  • Views 74
  • Downloads 0

How To Cite

Ali Etem GÜREL, Abdulaziz YILDIZ, Emrah DENİZ (2016). The Experimental and Theoretical Investigation of Effects on the Cooling Performance of Nozzle Structure in Adiabatic Cooling Systems. Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji, 4(3), 83-90. https://europub.co.uk/articles/-A-479240