The Impact of the Fire Source Location on Fire Development in a Large-Space Steel Commercial Building
Journal Title: Safety & Fire Technology - Year 2017, Vol 45, Issue 45
Abstract
Aim: The aim of this paper is to show that fire development in a large-space steel commercial building may have a different intensity depending on the location in which the fire originated. Buildings of this type are usually characterised by a large area with a relatively low height, which makes air circulation and fire-gas evacuation difficult. The low value of the opening factor in this case is an additional constraint preventing fire from developing freely. All this makes a localised fire which has not reached a flashover and for which the fire-plume-gas temperature has not become uniform throughout the fire compartment a representative pattern which should be considered to assess the fire safety of such buildings. Methods: This paper investigates the development of a localised fire which originates in three alternative locations differing in the position of the fire source and in the distance to the gate openings which ventilate the fire compartment. The FDS software is used for numerical fire modelling, specifying the time-varying spatial maps of the fire-plume-gas temperature on the basis of the equations taken from the fluid dynamics methodology with thermodynamic and aerodynamic variables. Results: The presented results, obtained hitherto, involve a steel commercial building which has no smoke vents, which are legally required, and sprinkler systems or any other active fire protection solutions. The plan for future works is to include additional formal components for modelling purposes to explore the impact of these safety measures on fire development. The fire-plume-gas temperature profiles associated with the individual fire locations investigated are linked for comparative purposes to the corresponding results yielded by the analytical models recommended by the professional literature. Conclusions: The obtained results seem to support the assertion that the modelling of a localised fire only on the basis of the existing analytical models does not necessarily lead to sufficiently reliable evaluations of the projected safety, particularly when this development depends on the factors which have not been accounted for in such models. An example of such a situation is the case investigated in this article, when the intensity of the anticipated fire depends on the location of the fire source, which involves varying oxygen availability necessary to sustain combustion.
Authors and Affiliations
Mariusz Maślak, Piotr Woźniczka
Ocena ryzyka zawodowego na stanowisku zbrojarz-betoniarz w przedsiębiorstwach wytwarzających wyroby na potrzeby budownictwa – studium przypadku
Cel: Omówienie wybranej problematyki oceny ryzyka zawodowego w przedsiębiorstwach wytwarzających wyroby na potrzeby budownictwa na podstawie studium przypadku stanowiska zbrojarz-betoniarz i produkcji budowlanych zbrojon...
Нормативное регулирование дислокации пожарных подразделений в Украине
Цель: Теоретическое описание нормативного регулирования дислокации пожарно-спасательных подразделений в населенных пунктах Украины. Введение: В статье приведены результаты научных разработок группы ученых Украинского нау...
Fire Tests and Classification of Vertical, Glazed Elements of Defined Fire Resistance Class
Aim: Presentation of technical know-how associated with principles of fire resistance testing and classification of vertical glazed elements. Discussion on the impact of the existing evaluation rules of...
The Influence of the Addition of Melamine and Silica in the Retanning of Leather on the Flammability and other Selected Properties of Leather
Aim: The purpose of the research was to determine the effect of the addition of melamine and silica in the retanning process on selected properties of leather with particular regard to flammability. The article presents...
Innowacyjna metoda dostarczania wody do spożycia w sytuacjach kryzysowych
Cel: Doniesienie wstępne dotyczące udzielenia prawa ochronnego na wzór użytkowy pt. „Tymczasowe mobilne stanowisko do uzdatniania wody do spożycia” szczególnie przydatne w sytuacjach kryzysowych, głównie powodzi, kiedy n...