The interaction between the indoor environment and building construction
Journal Title: Budownictwo o zoptymalizowanym potencjale energetycznym - Year 2014, Vol 1, Issue 1
Abstract
The project listed in the acknowledgment focused on monitoring the occurrence of various fungus genera within building constructions of residential, non-residential and historic buildings. Fungoid organisms found on indoor surface of building constructions are a serious aesthetic and constructional/structural disadvantage with enormous impact on the interior environment of exploitable space. They can be found not only in rooms of old buildings, but also in newly built or reconstructed areas, where one would not expect them. Greater amounts of fungoid organisms occurring in artificial environments are harmful to humans.Therefore professional information provided to the public concerning their harmful impact not only on construction materials, but also on human health is very necessary.
Authors and Affiliations
Stanislav Toth, Jaroslav Vojtus
Wykorzystanie pomp ciepła w budynkach jednorodzinnych
W artykule dokonano analizy modernizacji dotychczasowego systemu grzewczego z zastosowaniem pomp ciepła. Przedstawiono opis systemu ogrzewania przed i po modernizacji. Przeprowadzono również analizę efektu ekono...
The assessment of effect of selected elements on the heat losses
The paper presents the results of investigations on building’s heat losses. The heat balance conditions in selected buildings were observed. The factors which influence on heat losses in analysed buildings were...
Mnogofaktornye issledovania effektivnosti ventiliruemyh ograzdausih i svetoprozracnyh konstrukcij s aktivnoj rekuperaciej vyhodasego teplovogo potoka (Multi functional researches of efficiency of the ventilated envelopes and fenestration with active recovery of the leaving thermal stream)
For an assessment of efficiency developed according to the new principles of envelopes and fenestration offered by authors with use of technologies of active energy saving with active recovery of th...
Analiza rodzajów mikroinstalacji odnawialnych źródeł energii pod kątem prognozowanego okresu kosztów zwrotu z inwestycji
Dokonano oceny zasadności wykonania i eksploatacji mikroinstalacji odnawialnych źródeł energii o mocy 3 kW w postaci dachowej instalacji fotowoltaicznej oraz elektrowni wiatrowej . Zaproponowano przykładowe rozwiązania t...
Teploprovodnost’ penoplastov (Thermal conductivity of the foam plastics)
The relationships are obtained, which describe the dependence of the thermal conductivity of foam plastics on its density, thermal conductivity and density of its matrix, thermal conductivity of...