The Practicality of Using Cemented Polyethylene Liner in Cementless Metal Cup during Revision Total Hip Arthroplasty (A Mid‐Term Follow‐up Study)

Journal Title: Majallah-i jarrāḥī-i ustukhvān va mafāṣil-i Īrān - Year 2017, Vol 15, Issue 3

Abstract

Introduction: In some special situations during the revision total hip arthroplasty with well fixed, well oriented acetabular cementless cup, orthopedic surgeons may prefer to retain the well‐fixed cementless cup. The aim of this study was to report the follow‐up of some cases treated with such a technique during a 10‐year period. Methods: During 2004‐2014, all cases of revision total hip surgery performed in Sina Hospital, Tehran, Iran were evaluated. 14 of 82 cases (16.5%) had cemented polyethylene liner in cementless metal shell. The demographic data, reasons for use of such revision technique result was evaluated by Harris Hip Score. Results: The most common reason was osteolysis (64%), and the most common cause was impaired locking mechanism (65%). There were few complications (one osteolysis and one infection). In five cases (36%) constrained liner was added and in 10 cases (72%) allograft was needed. The final Harris Hip Scores was good or excellent in 78%. Only one dislocation was seen. Conclusion: Cemented cup in cementless shell can be used in revision hip arthroplasty in well‐fixed Acetabular shell situations with acceptable outcom.

Authors and Affiliations

Keywords

Related Articles

Comparison of Preoperative Methods of Intramedullary Nail Length Measurement and Determination of the Best Estimation in Femur and Tibia Fractures

Background: Tibial and femoral fractures are among the common fractures and are usually treated with intramedullary nails, being often treated by intramedullary nailing. This study was performed to determine the best pre...

Evaluation of Complications in Clavicle Fractures Following Open Reduction and Internal Fixation

Background & Objective: Open reduction and internal fixation of clavicle fractures are associated with various complications. The present study aimed to evaluate the prevalence of the complications caused by internal fix...

Outcome of Acute Acromioclavicular Dislocation Surgery by Modified Weaver-Dunn Technique

Background: Weaver-Dunn technique is one of the common methods for treatment of acute acromioclavicular joint (ACJ) dislocation. Several modifications of this technique have been already described. Because of shortcoming...

Biomechanical Effect of longitudinal meniscal tear with or without anterior Cruciate ligament tear in Knee (Finite Element Analyses)

Backgrounds: Characterization of mechanical behavior of meniscus is an important issue considering the significant role of meniscus in load bearing within the knee joint. Identification of mechanical change in meniscal t...

Pain Management in Total Knee and Hip Arthroplasty

In recent years, the management and treatment of pain in surgery, especially the painful operation of hip and knee replacement, has been highly sought after by pain and orthopedic surgeons and therefore is of paramount i...

Download PDF file
  • EP ID EP420854
  • DOI -
  • Views 107
  • Downloads 0

How To Cite

(2017). The Practicality of Using Cemented Polyethylene Liner in Cementless Metal Cup during Revision Total Hip Arthroplasty (A Mid‐Term Follow‐up Study). Majallah-i jarrāḥī-i ustukhvān va mafāṣil-i Īrān, 15(3), 74-77. https://europub.co.uk/articles/-A-420854