The Practicality of Using Cemented Polyethylene Liner in Cementless Metal Cup during Revision Total Hip Arthroplasty (A Mid‐Term Follow‐up Study)

Journal Title: Majallah-i jarrāḥī-i ustukhvān va mafāṣil-i Īrān - Year 2017, Vol 15, Issue 3

Abstract

Introduction: In some special situations during the revision total hip arthroplasty with well fixed, well oriented acetabular cementless cup, orthopedic surgeons may prefer to retain the well‐fixed cementless cup. The aim of this study was to report the follow‐up of some cases treated with such a technique during a 10‐year period. Methods: During 2004‐2014, all cases of revision total hip surgery performed in Sina Hospital, Tehran, Iran were evaluated. 14 of 82 cases (16.5%) had cemented polyethylene liner in cementless metal shell. The demographic data, reasons for use of such revision technique result was evaluated by Harris Hip Score. Results: The most common reason was osteolysis (64%), and the most common cause was impaired locking mechanism (65%). There were few complications (one osteolysis and one infection). In five cases (36%) constrained liner was added and in 10 cases (72%) allograft was needed. The final Harris Hip Scores was good or excellent in 78%. Only one dislocation was seen. Conclusion: Cemented cup in cementless shell can be used in revision hip arthroplasty in well‐fixed Acetabular shell situations with acceptable outcom.

Authors and Affiliations

Keywords

Related Articles

Outcomes of Open Reduction Internal Fixation in the Patients with Distal Femur Intra‐articular Fractures

Background: Distal femur intra‐articular fractures (DFIAFs) could be highly challenging. Despite the reports of effective treatment of these injuries, the patients are often faced with numerous complications. The present...

Biomechanical Effect of longitudinal meniscal tear with or without anterior Cruciate ligament tear in Knee (Finite Element Analyses)

Backgrounds: Characterization of mechanical behavior of meniscus is an important issue considering the significant role of meniscus in load bearing within the knee joint. Identification of mechanical change in meniscal t...

Prevalence of Congenital Foot Abnormalities in Newborns: (A Descriptive Study on 2025 Newborns in Northern Iran)

Background: congenital foot deformities are among the most common congenital abnormalities causing morbidities, disturbing the normal gait and affecting patients’ quality of life. The aim of our study was to find out the...

The Effect of Eight Weeks of Moderate and High Intensity Endurance Training On Biomechanical Properties of Femur in Old Male Wistar Rats

Background: Physical activity reduces the risk of bone fractures by decelerating the bone loss and enhancing muscle strength. Such activities promote the bone strength and bone density through bone stimulation. The prese...

The Quick and Convenient Method of Closed Femoral Intramedullary Nailing by the Innovative Set for Close Reduction of Long Bone Fractures

Introduction: The preferred method in fixation of some long bone fractures is using intramedullary nailing. The benefit of this method lies in its higher biomechanical stability, as well as preventing additional surgical...

Download PDF file
  • EP ID EP420854
  • DOI -
  • Views 84
  • Downloads 0

How To Cite

(2017). The Practicality of Using Cemented Polyethylene Liner in Cementless Metal Cup during Revision Total Hip Arthroplasty (A Mid‐Term Follow‐up Study). Majallah-i jarrāḥī-i ustukhvān va mafāṣil-i Īrān, 15(3), 74-77. https://europub.co.uk/articles/-A-420854