The Region of Interest in Determining the Proper Value of Full-Width at Half Maximum during Magnetic Resonance Spectroscopy

Journal Title: Journal of Medical Science And clinical Research - Year 2017, Vol 5, Issue 8

Abstract

Background: MRS is an advanced examination of MRI producing a spectra that describe metabolite information of tissues. ROI setting becomes very important in generating the spectral diagnostic value called Full-Width at Half Maximum (FWHM). All collected FWHM data will assist physicians to determine the stage of brain tumors. In clinical applications, Radiographers select several ROIs in obtaining FWHM values without any particular benchmark which directly affects the accuracy of the brain tumor stage. Objective: The purpose of this study is to examine the FWHM profiles based on the ROI selections and to determine the effect of selected ROIs on to FWHM values. Methods: This research is a quantitative study with an experimental approach. Data were collected by an expert Radiographer during 30 days in June 2016 at Department of Radiology, Siloam Hospital Kebon Jeruk Jakarta using a particular bottle phantom MRI 2000 ml. The phantom was scanned with 1.5 Tesla MRI scanner, from which various selection of the ROIs sized 20 mm, 25 mm, 30 mm, 35 mm and 40 mm; at the several positions. The positions employed were the centre, 12 o'clock, 3 o'clock, 6 o'clock and 9 o'clock. The analysis was performed to define the adequate size of ROI generating an optimum FWHM values. Linear regression applied to conclude whether or not there is an influence of the ROI size in generating FWHM values. Results: The results showed the optimum FWHM values of 12-20 were generated from the ROI size 20-30 mm at the center position. Regression analysis deemed significant (p-value <0.05) leading to a conclusion that the ROI size setting affects the FWHM values. The smaller the ROI size, FWHM value will decrease with higher homogeneity and vice versa. Conclusion: ROI size setting affects FWHM value, and optimum FWHM value is generated by ROI size of 20 – 30 mm at the center position.

Authors and Affiliations

Yeti Kartikasari

Keywords

Related Articles

A Study of Clinical Profile of Premature Presbyopia in A Tertiary Care Hospital

Purpose: To study the clinical profile of premature presbyopia in a tertiary care hospital. Materials & Methods: Three sixty patients with defective near vision below the age of 40 years who attended ophthalmology outpat...

Clinical Profile of Dengue in a Tertiary Care Hospital of Rohelkhand of U.P.(Bareilly)

Dengue fever has emerged as one of the major health problems in North India in recent years. The 2011 epidemic and beyond had created concern about the efforts regarding the prevention and treatment of this disease at th...

Hansens Disease – A Case Report

Hansens disease or leprosy is a chronic granulomatous disease involving skin, peripheral nerves, nasal mucosal and capable of effecting any organ.The disease reflects immune status of host, chemotherapy and host resistan...

Comparative study of Dot enzyme immune assay and Widal test in the diagnosis of Typhoid fever in a tertiary care hospital in south Kerala

Typhoid fever is acute and often life-threatening febrile illnesses caused by systemic infection with the bacteria Salmonella enterica serotype Typhi. The disease is endemic in the Indian subcontinent including Banglades...

Rare Presentation of Abdominal Tuberculosis (Ventral Hernia with Obstruction)

Abdominal tuberculosis continues to be a major problem in many regions of the world. The lack of specific signs and symptoms of abdominal tuberculosis involving the intestinal tract frequently leads to missed or delayed...

Download PDF file
  • EP ID EP529866
  • DOI -
  • Views 68
  • Downloads 0

How To Cite

Yeti Kartikasari (2017). The Region of Interest in Determining the Proper Value of Full-Width at Half Maximum during Magnetic Resonance Spectroscopy. Journal of Medical Science And clinical Research, 5(8), 27174-27179. https://europub.co.uk/articles/-A-529866