The Reliability of Smartphone and Goniometric Measurements of Hip Range of Motion

Journal Title: Journal of Rehabilitation Sciences and Research - Year 2016, Vol 3, Issue 4

Abstract

Background: Range of motion is an essential component of the hip examination. Handling issues with the goniometer often create challenges when measuring hip passive range of motion (PROM). Recent generations of smartphones have emerged as an alternative instrument for the measurement of joint ROM. The purpose of this study was to investigate the intra-rater, inter-rater and interinstrument reliability of smartphone and goniometric hip PROM. Methods: Two investigators measured hip PROM to a designated end position on 30 asymptomatic participants in a blinded within study design using two measurement methods, smartphone and goniometer. Relative reliability of smartphone and goniometric measurements of hip PROM was assessed using intraclass correlation coefficients (ICC). Absolute reliability of both measurement methods was assessed using paired t-tests, standard errors of measurement (SEM), and 95% limits of agreement (LOA). Results: Relative reliability ICCs ranged from 0.47-0.99 (intra-rater), 0.05- 0.99 (inter-rater) and 0.25 -0.97 (inter-instrument). Inter-rater differences of smartphone hip measurements were non-significant, however, significant differences were found for all inter-rater goniometric hip measurements (P<0.02). The comparison of the smartphone to goniometric measurements showed bias was present in 7 out to 12 hip measurements (P<0.04). SEM ranged from 1° to 3° (intra-rater, inter-rater, and inter-instrument). LOA ranged from -6.8° - 5.1° (inter-rater) and -8.9° - 13.8° (inter-instrument). Conclusion: These findings support intra-rater reliability of both instruments when measuring hip PROM. Inter-rater reliability, however, was supported only for the smartphone. Due to systematic bias of inter-instrument measurements performed by one rater, caution should be used if the instruments are to be used interchangeably in order to quantify within session hip PROM.

Authors and Affiliations

Elizabeth S Norris, Emily Wright, Shannon Sims, Megan Fuller, Kurt Neelly

Keywords

Related Articles

Comparing the Effects of Balance Training with and Without Cognitive Tasks on the Quality of Life and Balance Performance in Community- Dwelling Older Adults: A Single-Blind Randomized Clinical Trial

Background: Aging process can deteriorate the ability to maintain balance, specifically under dual-task conditions. Thus far, different methods of exercises therapy have been applied to improve balance performance of old...

Comparison of Reading Comprehension Skill of Students with Severe to Profound Hearing Impairment from Second up to Fifth Grade of Exceptional Schools with Normal Hearing Students

Background: Reading is known as one of the most important learning tools. Research results consistently have shown that even a mild hearing impairment could affect the reading skills. Due to the reported differences in r...

Comparison of Maximum Voluntary Contraction Positions for Serratus Anterior Muscle in Men with Scapular Dyskinesis: Electromyography Analysis

Background: The purpose of this study was to quantify the surface EMG activity of the serratus anterior muscle during two main test positions performed with the maximum effort by the subjects with scapular dyskinesis. Me...

Relationship between Quality of Life and Hypertonia in Young Adults with Spastic Cerebral Palsy

Background: The complications associated with spastic cerebral palsy can affect the physical ability and quality of life of individuals suffering from this motor disorder. The aim of this study was to assess the relation...

The Effectiveness of Limited Dynamic Wrist Splints on the Symptoms, Function, and Strength of Women with Carpal Tunnel Syndrome: A Controlled Trial Study

Background: Splinting is the most common conservative method of treating patients with mild and moderate Carpal Tunnel Syndrome (CTS). The aim of this study was to determine the effectiveness of the limited dynamic wrist...

Download PDF file
  • EP ID EP238331
  • DOI -
  • Views 101
  • Downloads 0

How To Cite

Elizabeth S Norris, Emily Wright, Shannon Sims, Megan Fuller, Kurt Neelly (2016). The Reliability of Smartphone and Goniometric Measurements of Hip Range of Motion. Journal of Rehabilitation Sciences and Research, 3(4), 77-84. https://europub.co.uk/articles/-A-238331