The use of three dimensional hysterosonography in recurrent implantation failure prior to in vitro fertilization cycles

Journal Title: Scholars Journal of Applied Medical Sciences - Year 2017, Vol 5, Issue 3

Abstract

Abstract: Recurrent implantation failure can be due to endometrial cavity abnormalities or abnormal endometrial thickness, hysteroscopy and hysterosonography can be used to evaluate the presence of endometrial polyps, submucousmyomas, endometrial cavity adhesions and abnormal endometrial thickness. The current study aimed to evaluate the value of performing 3D hysterosonography prior to in vitro fertilization cycle as an alternative tool to hysteroscopy. Referred 250 patients suffered from recurrent implantation failure and all were examined with 3D transvaginal ultrasound followed by 3D hysterosonography at day 8-10 of non-stimulated cycle prior to in vitro fertilization cycle.116 patients (43%) were detected with endometrial cavity abnormalities and abnormal endometrial thickness. All patients except 10 patients, (8 patients with thin endometrium and 2 patients with large mixed mural-submucosalmyomas) were subjected to hysteroscopy treatment and showed complete agreement between the findings of 3D hysterosonography and hysteroscopy.3D hysterosonography is a valuable alternative tool to hysteroscopy in evaluating endometrial cavity abnormalities and abnormal endometrial thickness in patients suffered from recurrent implantation failure of in vitro fertilization cycles. Keywords:Three dimensional: Hysterosonography: Hysteroscopy: In vitro fertilization cycle, implantation failure

Authors and Affiliations

Ashraf Talaat Youssef, Wessam Deeb

Keywords

Related Articles

Can Eosinopenia be used as an Indicator to Predict Mortality in Surgical Intensive Care Unit

The aim of this study was to test the efficacy of eosinophilic count as a broad indicator in prognosticating mortality in surgical intensive care unit (ICU). 437 patients admitted to the emergency ward were evaluated for...

Diagnosis of Tuberculous Pleural Effusion by analysis of Adenosine Deaminase in Serum and Exudative pleural effusion

Abstract: Various enzymes has evaluated by analyzing pleural fluid to diagnose Tubercular pleural effusion. Among different enzymes, Adenosine deaminase has been proven with higher specificity and sensitivity, to be a go...

Patient’s perceptive of operative management in soft tissue sarcoma

The expectations of the patient prior to surgical intervention can affect the final surgical outcome. This study evaluates the relationship between patient’s outcome expectations and health related quality of index. The...

A Comparative Study of Intestinal Parasitic Carriage in Pregnant-Non Pregnant Women

Intestinal parasitoses are a public health problem in developing countries. Our study aims to determine the frequency and contributing factors of intestinal parasitic infections in pregnant women are often exposed to the...

Comparison between Combined Supraclavicular-Interscalene Block versus Interscalene Block Under Ultrasound Guidance in Patients Undergoing Humerus Shaft Fracture Surgery

Abstract: Fractures of proximal upper extremity present a challenge to the anaesthesia provider when administering a regional anaesthetic because the dermatomal distribution of the upper extremity requires more local ana...

Download PDF file
  • EP ID EP371344
  • DOI -
  • Views 91
  • Downloads 0

How To Cite

Ashraf Talaat Youssef, Wessam Deeb (2017). The use of three dimensional hysterosonography in recurrent implantation failure prior to in vitro fertilization cycles. Scholars Journal of Applied Medical Sciences, 5(3), 730-737. https://europub.co.uk/articles/-A-371344