Tissue Processor Based Programmable Logic Control

Abstract

Tissue Processor Tissue Processor consists of several stages of dehydration, clearing, and paraffin infiltration. Phase dehydration to remove water content in tissues by immersion into alcohol. Clearing stage is the process of pulling out the alcohol content in the network by using a liquid xylol. Paraffin infiltration stages are the stage of filling cavities with liquid paraffin tissue. The purpose of this research is to modify the equipment that had broken before became useful equipment that uses basic controlled PLC. This modification tool-making using the one-group posttest design by treatment of the instrument without first measuring the initial state, the results of treatment directly measured without comparison to a control group. Making the modification tool using PLC as the main controller throughout the series. The tool mechanical motion using DC motors and AC motors as well as the use of two sensors limit switch as the controller limits the motor movement. Based on the results obtained temperature measurement error with the largest value of 4.44% in paraffin heater tube 1 and the biggest error of 4.0% in paraffin heater tube 2. While the measurement time of each - each tube obtained the smallest error on the tube-to-one by 0.03%, and the biggest error of measurement contained in the tube to the fourth, fifth, sixth, eighth and tenth of 0.16%

Authors and Affiliations

Neny Ferdianita, Her Gumiwang Ariswati, Tribowo Indrato

Keywords

Related Articles

Phototherapy Radiometer with AS7262 Sensor

The phototherapy is a device used in hyperbilirubinemia therapy by using blue light radiation with ranges between 425nm-475nm. The effectiveness of hyperbilirubinemia therapy depends on the amount of energy emitted by li...

Five Channel Temperature Calibrator Using Thermocouple Sensors Equipped With Data Storage

A temperature calibration device is a tool used to measure the accuracy of a temperature-related device such as a Sterilizer. This temperature calibration device is needed when the temperature in the Sterilizer is not li...

Portable Spirometer using Gas Pressure Sensor For FVC and FEV1 Measurement

Extreme climate change and air pollution caused by dust, smoke, vehicle exhaust gases, and industry can increase the chances of contracting various infectious diseases caused by viruses, especially respiratory infections...

Tissue Processor Based Programmable Logic Control

Tissue Processor Tissue Processor consists of several stages of dehydration, clearing, and paraffin infiltration. Phase dehydration to remove water content in tissues by immersion into alcohol. Clearing stage is the proc...

Waterbath Design equipped With Temperature Distribution Monitor (Temperature and Timer Control Parameters)

Waterbath is a device used to create a constant temperature. This tool is used to incubates in microbiology analysis. Temperature is maintained according to the desired range. The heating element is controlled by the hea...

Download PDF file
  • EP ID EP614907
  • DOI 10.35882/jeeemi.v1i1.5
  • Views 66
  • Downloads 0

How To Cite

Neny Ferdianita, Her Gumiwang Ariswati, Tribowo Indrato (2019). Tissue Processor Based Programmable Logic Control. Journal of Electronics, Electromedical Engineering, and Medical Informatics, 1(1), 21-27. https://europub.co.uk/articles/-A-614907